1.1.6 Setting of the internal standard interface
The default setting of the baud rate is
4800. The message on the right is
indicated for information purposes:
1.1.7 Programming of relay outputs for error messages
The main clock is fitted with 2 relay outputs that can be programmed for the following error
messages:
Supply:
power supply failure (24 V DC)
Ext. Fuse: failure of the secondary clock fuse ("SLAVE")
Int. Fuse: failure of the main fuse ("MAINS")
Low Batt.: accumulator voltage too low
Programming of the relay outputs for the error messages:
1. Remove the write protection (
1.1.1).
2. Press the key
1
several times until
one of the two relay setting menus
appears on the display, for example:
3. Press the
ENTER
key for confirmation. The cursor starts flashing.
4. Press the key
2
to select from among the possible errors.
5. Press the
ENTER
key to confirm the selection.
To cancel the modification, press the
MENUE
key twice.
6. Press the
MENUE
key, to return to the date display.
1.3 Set-up of secondary clocks
1. Press the
MENUE
key for at least 4 s until the version number appears on the display.
2. Press the key
2
several times until
the analogue time setting menu
appears on the display.
3. Press the
ENTER
key. The following
display appears (for secondary
clocks on the terminals 32 & 33):
For analogue secondary clocks on
the terminals 7 & 8, press
1
or
2
once, until the message on the right
appears on the display:
4. Press the
ENTER
key. The following
display appears:
5. Set all secondary clockss by hand to a standardised time (e.g. 12:00).
Содержание 20097
Страница 1: ...Operating Instructions WEMPE digital main clock 20097 ...
Страница 40: ...WEMPE digital main clock 20097 Annex 40 V3 0 01 2011 1 3 Circuit boards 1 1 1 Main board Ill 11 Main board ...
Страница 42: ...WEMPE digital main clock 20097 Annex 42 V3 0 01 2011 1 1 3 Oscillator board Ill 13 Oscillator board ...
Страница 59: ...WEMPE digital main clock 20097 Notice V3 0 01 2011 59 Notice ...