background image

NOTE:

  DO NOT discard 

the carton or other packing 
materials until you have 
inspected the appliance for 
hidden damage and tested it 
for proper operation. 
Refer to 

SHIPPING DAMAGE 

CLAIM PROCEDURE 

on the 

inside front cover of this 
manual. 

 

 

CAUTION 

FIRE HAZARD 

 

Avoid storing flammable or 
combustible materials in, on or 
near the appliance. 
 

CAUTION 

ELECTRICAL 
SHOCK HAZARD 

 

The ground prong of the 
electrical cord is part of a 
system designed to protect 
you from electrical shock.  In 
the event of internal damage 
to the warmer.  NEVER CUT 
OFF THE GROUND PRONG 
(large round prong).  NEVER 
TWIST AND ELECTRICAL 
PRONG TO FIT AN 
EXISTING RECEPTACLE. 
Install an electrical circuit and/
or receptacle appropriate to 
the voltage/amperage 
requirements of the appliance. 
 

IMPORTANT: 

Damage due to 

being plugged into wrong 
voltage is NOT covered by 
warranty. 

INSTALLATION 

UNPACKING & INSPECTION 

 

Carefully remove the appliance from the carton.  Remove all  
protective plastic film, packing materials and accessories from the 
Appliance before connecting electrical power or otherwise performing 
any installation procedure. 

 
Carefully read all instructions in this manual and the 

Installation 

Instruction Sheet

 packed with the appliance before starting any 

installation. 

 
Read and understand all labels and diagrams attached to the 
appliance. 

 
Carefully account for all components and accessories before 
discarding packing materials.  Store all accessories in a convenient 
place for later use.

 

 

SET-UP NOTES 

 

     1.      Setup the appliance only on a firm, level, non-combustible     
              surface.  Verify local codes for requirements. Concrete, tile,  
              terrazzo or metal surfaces are recommended. Metal over      
              combustible material may not meet code for non-combustible 
              surfaces. 
 

       

2.    Refer to the 

Installation Instruction Sheet 

for required             

              clearances.  Maintain required clearances between the           
              appliance and adjacent combustible surfaces. 
 
       3.    Avoid storing flammable or combustible materials in, on or near 
              the appliance. 
 

ELECTRICAL HOOK-UP

 

 
       1.     Refer to the nameplate.  Verify the electrical service power.   
               Voltage and phase must match the nameplate specifications.  
               Plugging the warmer into the wrong voltage can severely       
               damage the unit or cause noticeable decreased performance. 
 
       2.     Your warmer is equipped with a grounded electrical cord.      
               This cord must be plugging into a properly grounded electrical 
               receptacle. 

031 306

484 OpM

a

n

ual 

for SH

W
-Serie

s

 W
a

rm
ers
 

Содержание Showroom SHW-11

Страница 1: ...are available from your WELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE Contact your WELLS DEALER if you have any questions concerning installat...

Страница 2: ...rements and wiring diagrams supplied with the equipment are not covered by this warranty 4 Replacement of items subject to normal wear to include such items as knobs light bulbs and normal maintenance...

Страница 3: ...nsistent maintenance of this appliance will ensure that it gives you the very best performance and a long economical service life This manual contains the information needed to properly install this a...

Страница 4: ...the TEMPERATURE CONTROL KNOB The knob has an indicator line which points to general temperature settings 3 The dial will rotate approximately 300 and will reach a stop at both ends The OFF position i...

Страница 5: ...ctrical power before performing any maintenance or servicing There are no user serviceable components in this appliance In all instances of damage or malfunction Contact Wells Service Dept 888 492 278...

Страница 6: ...re Carefully read all instructions in this manual and the Installation Instruction Sheet packed with the appliance before starting any installation Read and understand all labels and diagrams attached...

Страница 7: ...e control to HIGH 4 Allow warmer to preheat for 30 minutes then set the control for the desired temperature Be sure to keep the warmer covered during preheat and operation OPERATION 1 Always use an pa...

Страница 8: ...Rinse warmer thoroughly with a vinegar and water solution to neutralize all detergent cleanser residue 4 Inspect warmer tank for damage Damage to the outer body may allow grease and water to leak int...

Страница 9: ...control OFF Cover pans 4 Allow solution to soak at least one hour or overnight for heavy scale buildup 5 Drain hot water from pans Scrub with a plastic scouring pad Rinse thoroughly with hot water the...

Страница 10: ...leaking or other internal damage Contact Wells Service Dept 888 492 2782 for repairs Internal damage Contact Wells Service Dept 888 492 2782 for repairs Warmer slow to heat Mineral deposits on pan act...

Страница 11: ...ill rust pit and corrode under the following conditions Poor Water Quality Hard water water with a high content of dissolved minerals will leave mineral deposits when allowed to dry Calcium lime can b...

Страница 12: ...NSET ADAPTER TOP 20175 ONE 4 QT INSET ADAPTER TOP 20822 RECTANGULAR ADAPTER TOPS FOR SHW 1220 ONE 4 QT AND ONE 11 QT INSET ADAPTER TOP 23138 ONE 7 QT AND ONE 11 QT INSET ADAPTER TOP 23139 TWO 7 QT INS...

Страница 13: ...g for service RESTAURANT _____________________________ LOCATION _____________ INSTALLATION DATE ________________________ TECHNICIAN ___________ SERVICE COMPANY ________________________________________...

Страница 14: ...PRINTED IN CHINA...