FRESH WATER SYSTEM
The fresh w ater system consists of a w ater
tank, pump, water heater, and a distribution sys-
tem. Fresh water is supplied to various areas
including the galle y, the head, and a transom
shower. Some models ha ve male hose connec-
tions for cockpit and foredeck w ashdown. Check
with your dealer if you ha ve a question about
your water system.
The tank is filled through a deck plate. The loca-
tion of the fresh w ater fill and vent deck plate
will vary by model. The fill plate will be labeled
WATER and is on a deck surface.
IMPORTANT:
Fill the tank with only fresh w ater.
Refilling the tank often will help k eep it a source
of fresh and clean drinking w ater.
The fresh w ater pump supplies w ater under
pressure to the system when the dockside
water supply is not connected. The FRESH
WATER PUMP breaker switch on the DC CON-
TROL panel controls its operation.
Before entering the pump, the w ater passes
through a filter to capture an y contaminants.
when the break er is switch to ON, the pump
runs until the hot and cold w ater systems are
pressurized. An automatic pressure switch
shuts the pump off until the pressure drops to a
preset level (for example, a pressure drop
caused by opening a faucet). The pump will then
run again until the system is pressurized and
turn itself off.
If the pump r uns from time to time e ven though
no water is being used, a leak in a w ater line is a
likely cause. Check all lines for a leak and repair .
IMPORTANT:
Operate the fresh w ater pump only
when there is w ater in the tank. Running the
pump dry will damage the impeller . The pump will
not automatically tur n off when the tank is empty .
If the break er switch is left on when the tank is
empty, the pump ma y overheat.
SANITIZING FRESH WATER SYSTEM
The fresh w ater system should be sanitized
before initial use, after winter storage or when
system has not been used for extended periods
of time.
NOTE:
The water tank must be empty before
beginning the sanitizing process.
1. In an appropriate size buck et, make a solu-
tion of 1-1/4 cups (10 oz.) of household
bleach and 5 gallons (19 liter s) of fresh
water.
2. Dump water into w ater tank and allow
treated water solution to remain in w ater
tank for 3 to 4 hour s.
3. Use faucet pump to bleed air from the fresh
water line.
4. Drain treated w ater solution from lines and
empty tank.
5. Flush entire system with fresh w ater.
IMPORTANT:
Thoroughly flush entire system
with fresh w ater after each sanitizing process.
If fresh w ater has an excessive chlorine taste
after sanitizing the system:
4-11
PROBLEM
No power to A C devices
(Continued)
Inadequate power to A C
devices (generator r un-
ning)
No power at A C outlets
CAUSE
Loose or disconnected
wire
Electrical demand greater
than generator output
Outlet breakers in AC CON-
TROL panel OFF
Ground fault inter rupter
tripped
SOLUTION
Tighten connections. See your dealer .
Switch off de vices and equipment not
needed.
Switch breakers to ON.
Reset button on outlet and test.
AC ELECTRICAL SYSTEM CONT’D
60305-Fishboat-04_05_Sect 1/13/04 3:27 PM Page 4-11
Содержание 180 SPORTSMAN O/B
Страница 1: ...60305 Fishboat Cover 1 30 04 2 12 PM Page 1...
Страница 13: ...1 9...
Страница 14: ...1 10 SERVICE MAINTENANCE LOG HOUR METER DATE READING SERVICE REPAIRS PERFORMED...
Страница 16: ...1 12 FUEL LOG HOURS FUEL RANGE DATE RUN GAL MI RPM MPH GPH...