SMP Encoder & Transcoder Quick Installation Guide 

V1.0-N 

 

Pic-2.3-2 

Parameters Description 

ChannelSelect 

In this ‘ChannelSelect’, user can select a channel to configure its 

parameters. 

Enable 

On: enable the IP receiving function. 

Off: disable the IP receiving function. 

Note: this parameter setting applies to all channels. 

Channel configuration 

EnableChannel 

Enable or disable corresponding input channel 

SourceIPAddress 

Set the IP address of the multicast/unicast that are going to 

receive 

SourcePort 

Set port of multicast/unicast 

Protocol 

Select UDP/RTP for multicast/unicast 

ColPortMatching 

If the output IP stream quality looks not as good as the input 

stream, user can select to ‘Enable’ these two options then to 

enable the FEC function.   

RowPortMatching 

Содержание SMP260

Страница 1: ...Digital Encoder Transcoder Quick Installation Guide...

Страница 2: ...s been correctly grounded before switching on the device PIC 1 1 1 To mount the unit to a 19 42U rack please perform the following steps 1 Make sure the mounted rack surface is stable and can support...

Страница 3: ...al devices The equipment and all connected external devices are required grounded Turn on the devices only after the wiring connection is completed Otherwise the device may be damaged Follow the below...

Страница 4: ...connected should be without large data processing The TS IP port can work for input and output simultaneously User only needs to connect one RJ45 cable to the TS IP port of the device 1 3 Power Conne...

Страница 5: ...ete If the unit fails to initialize and hangs at the booting stage swtiching off the device and then powering up again may help If the device still fails to initialize please contact your service repr...

Страница 6: ...use the button on the front panel to change the IP gateway and subnet mask The gateway should be the same as the management PC s The subnet mask should be the same as the management PC s s The IP and...

Страница 7: ...e required Default User Name and Password are admin PIC 2 2 1 o Choose Remember Me if user wants to directly log on the NMS without inputting the user name and password o Select Login to log on the de...

Страница 8: ...isted in this area by its IP address 3 Parameter setting and configuration area The parameters of the equipment are shown and configured here by selecting different tabs This is the main operation are...

Страница 9: ...grams you transfer from input port to output port in Program Info is more than the output bit rate of some channel you set in sub board Communicate Status indicates the communication status between NM...

Страница 10: ...only to the corresponding channel Video Source To select the correct video input source Audio Source To select the correct audio input source Encode Mode Select CBR or VBR for the encoding mode Video...

Страница 11: ...the input source The frame rate should be the same as that of input source GOP Size To edit the GOP size 1 There are four different encoder modules for the device SDI CVBS module MPEG 2 SD CVBS module...

Страница 12: ...arameter setting applies to all channels Channel configuration EnableChannel Enable or disable corresponding input channel SourceIPAddress Set the IP address of the multicast unicast that are going to...

Страница 13: ...P stream Pic 2 3 3 Following are the key parameters that need to change to meet with the application need in first time setup Parameters Description ChannelSelect In this ChannelSelect user can select...

Страница 14: ...ut program window to the output program window b Set button to apply the changes to the NMS The setting will lose if the NMS is close or the equipment is powered off c To obtain refresh the current pa...

Страница 15: ...t Program Configuration The Input Program Configuration is on the left side of the Program Info window It displays all the inserted modules information and the received input streams Pic 2 3 5 SD Enco...

Страница 16: ...nserted module will be displayed after the Board No b For empty slot no Board No will be displayed c Port No represents each physical port of the inserted module d Scan the input TS after the paramete...

Страница 17: ...ion Guide V1 0 N Pic 2 3 6 Output program configuration Select the port which you want to transmit the output stream Pic 2 3 7 Select a TS stream click the mouse right button In the pop up menu select...

Страница 18: ...input Original Network ID and TS ID will be assigned to the selected output TS channel Pic 2 3 10 To change the Original Network ID and TS ID use the left mouse button to click the TS channel name wh...

Страница 19: ...h is going to be transmitted on the left hand side Input Program Info window and select the port TS channel which are going to carry the transmission on the right hand side Output Program Info window...

Страница 20: ...can set the selected input stream to be transmitted at any assigned output TS channel Note This Quick Installation Guide only contains tutorials with simple instructions for device installation and c...

Отзывы: