Manual no. WM070401
Page
15
CoolArc200
4-6. Extension Welding Cable Selection Chart
CAUTION!
Use shortest cable possible.
Turn off power before connecting to
weld output terminals!
Welding cable size in
AWG (mm
2
)
Maximum total cable (Copper) length in weld circuit allowed
in Ft(M)
Welding Amperes (A)
100
200
6(13)
260(80)
130(40)
4(20)
330(100)
160(50)
3(30)
410(125)
200(60)
Table 4.2