3
5
1
2
3
4
6
7
8
9
10
OPERATING INSTRUCTIONS
General Parts Drawing
ITEM #
DESCRIPTION
FUNCTION
1.
On-Off Toggle Switch
Controls electrical power to kettle.
2.
Solid State Temperature
This control allows the operator to adjust the kettle temperature in
Control Knob
increments from MIN. to MAX. (see Temperature Range Chart on
page 4 of this manual.
3.
Heat Indicator Light (Green)
When lit, indicates that the kettle burner is on.
Cycles ON-OFF with burner.
4.
Low Water Indicator Light (Red)
When lit, indicates that the kettle is low on water and will not operate
in this condition (see Reservoir Fill Procedures on page 13 of this
manual).
5.
Vacuum/Pressure Gauge
Indicate steam pressure in PSI inside steam jacket as well as
vacuum in inches of mercury.
6.
Pressure Relief Valve
This valve is used to vent the kettle and in the unlikely event there is
an excess steam build-up in the jacket, this valve opens
automatically to relieve this pressure.
7.
Plug Nut
Plug nut is used for refilling the kettle with water (see "Kettle Venting
Instructions" and "Reservoir Fill Procedures" on pages 13 and 14 of
this manual).
8.
Tilting Handle
Used for tilting the kettle.
9.
Marine Lock
Prevents unit from accidental tilting.
10.
Water Level Sight Glass
Displays water level in steam jacket.
Содержание Cleveland Range KGT-12-T