RESERVOIR FILL
PROCEDURES
The kettle's water level must be maintained at the
proper level. Under normal operating conditions, the
sealed water reservoir should never require the addition
of water.
If the red "low water" light comes on during use (while
the kettle is in an upright position), the water level has
reached a critically low level. The low water protection
control has automatically shut off the gas burner. The
following procedure must be completed before further
use:
NOTE:
Have a qualified service technician repair the
leakage problem and add water to the unit. Ensure that
the red "low water" light is on when the kettle is upright.
On tilting kettles, it is normal for the red light to come on
when the kettle is in a tilted position.
CAUTION:
Only distilled water should be used when
adding water to a partially filled water reservoir (If unit is
completely empty see Kettle Jacket Filling & Draining
Procedures on page 15). Local tap water conditions
may cause kettle damage which is not covered under
warranty. Rust inhibitor is purchased locally. Read
directions and do not exceed manufacturer's
recommendation (excessive rust inhibitor can also
cause solidification).
DISTILLED WATER REQUIREMENTS
Kettle
When Red “Low Water Light”
Capacity
comes on, add Distilled Water
6 gallon
70 ounces
12 gallon
120 ounces
1.
Ensure kettle is at room
temperature and pressure
gauge showing zero or
less pressure.
2.
Shut off power to the kettle at the fused
disconnect switch.
3.
Unscrew and remove plug
nut from top of pressure
gauge assembly.
4.
With kettle in the upright position, add a
mixture of distilled water and rust inhibitor
through the plug nut hole with a funnel.
5.
Fill the unit to the high
level mark on the sight
glass.
6.
Replace plug nut and carefully tighten. Do not
over tighten.
7.
Restore power to the kettle.
8.
The kettle must now be vented. Refer to the
Kettle Venting Instructions (page 14).
DANGER:
PRESSURE RELIEF
VALVE WILL EXHAUST HIGH
TEMPERATURE STEAM. CONTACT
WITH SKIN COULD RESULT IN
SERIOUS BURNS. KEEP FACE,
HANDS AND BODY CLEAR OF DISCHARGE.
DANGER:
WORKING ON MACHINES
WITH POWER COULD RESULT IN
SEVERE ELECTRICAL SHOCK.
13
Plug Nut
Sight
Glass
WARNING:
IMPROPER REFILLING OF
KETTLE JACKET WILL RESULT IN
IRREVERSIBLE DAMAGE TO UNIT.
50
0
100
150
200
250
300
350
400
40
50
60
0
10
20
30
psi
kPa
V
EN
T
A
IR
Содержание Cleveland Range KGT-12-T