2

Installation must be in accordance with local codes
and/or the National Fuel Gas Code ANSI Z223.1 Latest
Edition (USA) or the latest Installation Codes for Gas
Burning Appliances and Equipment CAN/ CGA B149.1
and CAN/ CGA B149.2 (Canada). Use a gas pipe joint
compound which is resistant to L.P. gas. Test all pipe
joints for leaks with soap and water solution. Ensure that
the gas pressure regulator is set for the manifold
pressure indicated on the gas rating plate. 

The appliance and its individual shut-off valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of 1/2 psi (3.45 kPa). The appliance must be
isolated from the gas supply piping system by closing
its individual manual shut-off valve during any pressure
testing of the gas supply piping system at test
pressures equal to or less than 1/2 psi (3.45 kPa).

ELECTRICAL

ENSURE THE ELECTRICAL SUPPLY MATCHES THE
KETTLE'S REQUIREMENTS AS STATED ON THE
RATING LABEL.

A cord and plug are supplied with the unit. Simply plug
the unit into any grounded outlet rated for a minimum of
10 amps. The wiring diagram is located on the back of
the console access panel. 

WARNING:

Electrical Grounding Instructions.

This unit is equipped with a three-prong (grounding) plug
for your protection against shock hazard and should be
plugged directly into a properly grounded three-prong
receptacle. Do not cut or remove the grounding prong
from this plug. Standard supply voltage is 115 volts A.C.,
however, optional A.C. voltages can be supplied on
special order. A separate fused disconnect switch must
be supplied and installed in the high voltage electrical
supply line. The kettle when installed, must be electrically
installed and grounded in accordance with local codes,
or in the absence of local codes, with National Electrical
Code, ANSI/NFPA 7-1990 (USA) or the Canadian
Electrical Code, CSA C22.1, Part 1 (Canada). 

VENTILATION

Gas fired kettles are only to be installed under a
ventilation hood in a room which has provisions for
adequate make up air. Further information can be
obtained by referring to the U.S.A. National Fire
Protection Associations NFPA96 regulations. These
standards have also been adopted by the National
Building Code in Canada.

WATER

The sealed jacket of the gas-fired kettle is precharged
with the correct amount of a water-based formula, and

therefore, no water connection is required to the kettle
jacket. The kettle can be equipped with optional hot and
cold water taps, the taps require 1/2" copper tubing as
supply lines.

INSTALLATION CHECKS

Although the kettle has been thoroughly tested before
leaving the factory, the installer is responsible for
ensuring the proper operation of kettle once installed. 

DO NOT ATTEMPT TO OPERATE THIS APPLIANCE
DURING A POWER FAILURE.

KEEP APPLIANCE AND AREA FREE AND CLEAR OF
COMBUSTIBLES.

1.

Supply power to the kettle by placing the fused
disconnect switch to the "ON" position. 

2.

Before turning the kettle on, read the
vacuum/pressure gauge. The gauge's needle
should be in the green zone. If the needle is in the
"VENT AIR" zone, follow air venting procedure. 

3.

Place the kettle's power on/off switch to the "ON"
position. 

4.

Turn the temperature control knob to "MIN .". The green
LED light should remain lit, indicating the burner is lit,
until the set temperature is reached. Then the green
light will cycle on and off, indicating the burner is
cycling on and off to maintain temperature. 

5.

Tilt the kettle forward. The red "LOW WATER" light
should be lit when the kettle is in a tilted position.
This light indicates that the burner has automatically
been shut off by the kettle's safety circuit. This is a
normal condition when the kettle is in a tilted
position. 

6.

Raise the kettle to the upright position. The red "low
water" light should go out when the kettle is upright.
If the red light remains lit in the upright position, it
indicates a low water condition, and water must be
added to the reservoir before the kettle can be
operated. Refer to the "Reservoir Fill Procedures", on
the kettle's label, for details. 

7.

Turn the temperature control knob to "MAX." and
allow the kettle to preheat. The green light should
remain on until the set temperature is reached. Then
the green light will cycle ON and OFF, indicating the
burner is cycling ON and OFF to maintain
temperature. 

CLEANING

After installation the kettle must be thoroughly cleaned
and sanitized prior to cooking. See complete cleaning
instructions in this manual (page 5).

Содержание Cleveland Range KGT-12-T

Страница 1: ...INSTALLATION OPERATION AND SERVICE MANUAL GAS TABLE TOP KETTLE MODEL KGT 6 T KGT 12 T CLEVELAND RANGE INC 1333 East 179th St Cleveland Ohio U S A 44110 Toll Free 1 800 338 2204 SE95010 Rev 3...

Страница 2: ...EVELAND RANGE TECHNICIAN RETAIN THIS MANUAL FOR YOUR REFERENCE WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installatio...

Страница 3: ...Service Parts Warranty 6 Faucet Assembly 6 Main Components 7 Console 8 Component Mounting Bracket Assembly 9 Piping Assembly 10 Maintenance Inspection Maintenance Check List 11 Calibrating Procedure 1...

Страница 4: ...per make up air flow Do not obstruct the flow of combustion and ventilation air Check rating plate to ensure that kettle has been equipped to operate with the type of gas available at the installation...

Страница 5: ...otection Associations NFPA96 regulations These standards have also been adopted by the National Building Code in Canada WATER The sealed jacket of the gas fired kettle is precharged with the correct a...

Страница 6: ...er and will not operate in this condition see Reservoir Fill Procedures on page 13 of this manual 5 Vacuum Pressure Gauge Indicate steam pressure in PSI inside steam jacket as well as vacuum in inches...

Страница 7: ...his light indicates that the burner has been automatically shut off by the kettle s safety circuit It is normal for the red light to come on when the kettle is in a tilted position However the kettle...

Страница 8: ...Rinse kettle interior thoroughly then drain the rinse water 7 Using mild soapy water and a damp sponge wash the exterior of the kettle rinse and dry 8 Leave the cover off when the kettle is not in use...

Страница 9: ...n factory supplied replacement parts will void warranty FAUCET ASSEMBLY ITEM PART DESCRIPTION QTY NO NO 1 KE50825 2 3 4 Spout 1 2 FA95022 Retaining Ring 1 3 FA05002 19 O Ring 1 4 KE51736 Long Faucet N...

Страница 10: ...0 2 Handle 6 gallon 1 KE54670 3 Handle 12 gallon 1 12 FA05002 29 O Ring for Handle 1 13 KE95457 Label 1 14 FA11258 Hex Capa Screw 14 20x3 4 lg 4 15 SA95116 Marine Lock Replacement Kit 1 16 KE50997 Blo...

Страница 11: ...g 2 8 KE50568 1 L E D Green 1 9 KE53469 2 Ignition Control Box 1 10 KE54308 High Voltage Lead Assembly 1 11 KE54309 Low Voltage Lead Assembly 1 12 WH KGT Wiring Harness 1 13 F01518 1 Gas Shut Off Valv...

Страница 12: ...927 Component Plate Weldment 1 2 KE50753 7 Relay 1 4 KE53838 20 Transformer 120 24 1 KE53838 18 Transformer 220 24 1 5 KE53838 19 Transformer 120 16 1 KE53838 21 Transformer 220 16 1 6 KE00458 Solid S...

Страница 13: ...t Elbow 3 4 NPT 1 8 KE01929 Feed Pipe Assembly 1 9 KE01500 2 Gas Burner Assembly 12 gallon kettle 1 KE01500 3 Gas Burner Assembly 6 gallon kettle 1 10 KE53406 11 Gas Orifice Natural Gas 12 gallon kett...

Страница 14: ...LT HANDLE Check handle for tightness If loose apply lock tight and reinstall Check handle knob is on end of handle and firmly tightened If loose apply lock tight and reinstall PRESSURE GAUGE Check tha...

Страница 15: ...s pressure relief valve We recommend this test be performed twice a year NOTE The following instruction is intended for use by qualified service personnel WARNING Kettle surface will be hot and steam...

Страница 16: ...irections and do not exceed manufacturer s recommendation excessive rust inhibitor can also cause solidification DISTILLED WATER REQUIREMENTS Kettle When Red Low Water Light Capacity comes on add Dist...

Страница 17: ...cycles ON stop venting and wait for kettle to cycle OFF before continuing 50 0 100 150 200 250 300 350 400 40 50 60 0 10 20 30 psi kPa V E N T A I R DANGER PRESSURE RELIEF VALVE WILL EXHAUST HIGH TEMP...

Страница 18: ...gallon 1 5 5 70 12 gallon 2 19 8 3 WARNING IMPROPER REFILLING OF KETTLE JACKET WILL RESULT IN IRREVERSIBLE DAMAGE TO UNIT 15 KETTLE JACKET FILLING DRAINING PROCEDURES DANGER EXTREMELY HOT SURFACES WOR...

Страница 19: ...resistance from 0 to 50 000 ohms This resistance is compared to the resistance on the thermistor using a voltage comparator circuit inside the control box If the resistance is lower than the thermisto...

Страница 20: ...FICE FITTING and remove MAIN ORIFICE Install new orifice from kit 7 Replace BURNER Check ORIFICE BURNER alignment insuring ORIFICE points straight into the center of the BURNER 8 Reconnect to gas supp...

Страница 21: ...18 WIRING DIAGRAM...

Отзывы: