10.
F/ SAFETY VALVE
Installation Check:
Pressure Relief Valve Periodic Testing Procedure
1.
With the kettle empty, set On-Off Switch/Temperature Control to "10"
(Max.). Allow the kettle to heat until the unit cycles off.
2.
Switch On-Off Switch/Temperature Control to "0" (Off) and disconnect main
power at fused disconnect switch.
3.
Stand to the side of the pressure relief valve discharge tube and pull
valve open for a maximum of one second. Repeat test three to four
times. Each time the mechanism should move freely and be
accompanied by a rapid escape of steam.
If valve appears to be sticking replace pressure relief valve.
If foreign material is discharged then drain kettle and replace pressure
relief valve.
✔
✔
✘
1
Plug
✘
Plumbed to drain
or water line
2
Tube
diameter
reduced
✘
3
Physical Checks
1.
Check that the PSI rating
on the valve matches
MAWP (maximum
allowable working
pressure) on the plate
welded to the kettle.
2.
Check that the Safety
Valve has a "UV" stamp.
3.
Check that the valve is
not damaged in any way.
If any of the above criteria
is not met, replace valve.
The above illustrations show the
variations of factory installed Safety
Valves.
Any modifications are
unacceptable.
4"
maximum
length
Correct
Installation
Incorrect Installation
✔
Probe
fully
inserted
in tube
Wiring is properly
connected
E/ SAFETY THERMOSTAT
Installation Check
:
Incorrect Installations
1.
Safety thermostat probe
is not completely
inserted into tubing
(except KET-3-T that
has a small loop).
2.
Safety thermostat probe
is removed from tubing.
3.
Safety thermostat
electrical connection is
bypassed.
Correct
Installation
✘
Probe
removed
partially
✘
Probe
removed
completely
✘
Thermostat
electrically
bypassed
1
2
3
Содержание Cleveland KGT12TGB
Страница 27: ...26...