background image

          

User manual 

 

       

TAXI-CHECK – V1.3

 

                                           

           - 3

 -   

 
 
 
 
Chapter 5 

Error messages   ……………………………………………............ 

5.1  Error 1   …………………………………………………… 
5.2  Error 2   …………………………………………………… 
5.3  Error 3   …………………………………………………… 
5.4  Error 4   …………………………………………………… 
5.5  Error 5   …………………………………………………… 
5.6  Error 6   …………………………………………………… 
5.7  Error 7   …………………………………………………… 
5.8  Error 8   …………………………………………………… 
5.9  Error 9   …………………………………………………… 
5.10  Error 10   …………………………………………………… 
5.11  Error 11   …………………………………………………… 
5.12  Error 12   …………………………………………………… 

 
Chapter 6 

Specifications   ……………………………………………………….. 

6.1  Handheld meter unit   ……………………………………… 
6.2  Roller bed unit   …………………………………………. 

 
Chapter 7 

Service   ………………………………………………………………. 

 

 

 

 

 

 

 
 

 
 

 

 

 
 
 
 
 
 
 
 
 
 

 
 
18 
18 
18 
18 
18 
19 
19 
19 
19 
19 
20 
20 
20 
 

 

21 
21 
21 

 

 

22 

Содержание TAXI-CHECK

Страница 1: ...TAXI CHECK Taxi Fare Meter Test System V1 3 USER MANUAL...

Страница 2: ...est 3 2 Quick meter test 3 3 Start time test 3 4 Setup f f tariffs 3 5 Hardware setup 3 6 View test data Chapter 4 Hardware setup menu options 4 1 Set rf channel 4 2 Set rf power 4 3 Contrast adjust 4...

Страница 3: ...Error 2 5 3 Error 3 5 4 Error 4 5 5 Error 5 5 6 Error 6 5 7 Error 7 5 8 Error 8 5 9 Error 9 5 10 Error 10 5 11 Error 11 5 12 Error 12 Chapter 6 Specifications 6 1 Handheld meter unit 6 2 Roller bed un...

Страница 4: ...User manual TAXI CHECK V1 3 4 1 0 Introduction to TAXI CHECK...

Страница 5: ...ress momentarily whilst in menu to scroll upwards Press momentarily to decrements value when in set up screens Hold down for 2sec for repetitive decrementing DOWN Press momentarily whilst in menu to s...

Страница 6: ...n back to the main menu press the CLEAR key Step 1 1 Use the DOWN or UP key to rotate to the desired preset Press ENTER to select and proceed to step 2 To return to step 1 press the CLEAR key Step 1 2...

Страница 7: ...ore the final value press ENTER and proceed to step 3 To return to step 2 press the CLEAR key Step 3 Using the DOWN or UP key increase or decrease the increment rate then press ENTER to continue to st...

Страница 8: ...ENTER key Throughout different stages of the test the user may be asked to reduce the vehicles speed These speed guidelines should be followed or the test may be automatically terminated The test can...

Страница 9: ...start a distance measurement test without having to enter any pre test values Only the distance traveled is stored in the results field meters over under or pass fail cannot be calculated At the main...

Страница 10: ...lect the desired option and press ENTER If you want to restart that test without saving the results then select option 2 restart test this will return the user to step 1 Otherwise select option 1 stor...

Страница 11: ...ect option 2 restart test this will return the user to step 1 Otherwise select option 1 store results to save test data and advance to step 3 Step 3 Since the system only has the ability to save tests...

Страница 12: ...r the DOWN or UP key accordingly When the desired value is met press the ENTER key and proceed to step 3 To exit without modifying and values press CLEAR to return to step 1 Step 3 The cursor will now...

Страница 13: ...n will appear Press CLEAR or ENTER to exit Step 1 All tests stored from the last test set can be viewed from this screen Use the DOWN or UP key to scroll to the desired test and press the ENTER key Pr...

Страница 14: ...ore and return to the hardware setup menu To exit without any modification press the CLEAR key Warning The set channel on the meter must always match the set channel on the roller bed electronics to o...

Страница 15: ...this option the hour s value will be highlighted by the flashing cursor this is the value that will be modified first Use the DOWN or UP key accordingly to modify the hours When the desired value is m...

Страница 16: ...the string Press ENTER to move onto the next character To store the modified string when finished hold down the ENTER key To exit without any modification press the CLEAR key 4 9 Calibration This opt...

Страница 17: ...ications When this option is entered the handheld meter will automatically poll the roller bed for the specs The screen below will appear briefly while the data is being downloaded If the roller bed c...

Страница 18: ...or quick meter test The likely causes are power failure to the base unit or external rf interference The handheld meter will advance to error 1 and start searching for the unit 1 Try repeating the ca...

Страница 19: ...not slow down during Error 6 the following message will appear This is the last warning given to the user before the test will abort 5 8 Error 8 The roller bed unit has failed to detect the calibrati...

Страница 20: ...that the rotary encoder is secured properly on the calibration jig 2 Ensure the coupling between the encoder and the calibration wheel is tight 3 Check the calibration jig is plugged in properly 4 Che...

Страница 21: ...e rate required by the NiMh batteries for 14 hours On completion the unit continues to trickle charge This ensures the batteries remain fully charged if left on charge when not in use It is recommende...

Страница 22: ...t is treated with care and is used in accordance with the instructions provided This unit has no user serviceable parts and should not be dismantled In the event that your Taxi Check system requires s...

Отзывы: