background image

Document No.: CWL-URM-04A

   |   

Revision No.: 00.

   |   

Revision Date: 20.06.2022

Document No.: CWL-URM-04A

   |   

Revision No.: 00.

   |   

Revision Date: 20.06.2022

21

22

17. Warranty 

19. Serviceability

Our products are well tested and they come with reasonable confidence from us that they 

are free of defects at the time of distribution. The product you bought is warranted for one 
year from the date of purchase. During this one year, the company is liable to replace the 
device or provide a refund to you for any major failure of the device. You also have the right 
to get the product repaired or parts replaced if they fail to operate at acceptable level of 

quality without being qualified as major failure.

The warranty is not transferrable and so it is extended only to the original user. You are 
entitled to the warranty only against original parts. The warranty stands void if any part of the 
device has been opened and repaired or replaced by the customer or unauthorized third 
party technician. Additionally, the warranty will also be voided if the device is misused or 
abused in any form.
If the device was bought online, the customer has to make the arrangements and bear the 
expenses for returning the product. In case of an approved replacement, the customer has 
to also bear the expenses for delivering the replacement. If the device was bought from an 
authorised dealer, the customer may return the device to the dealer.
Please ensure that you have read and tried the troubleshooting steps mentioned in the 
'Troubleshooting' chapter of this manual before approaching us for exercising the warranty. 
If the device is not turned on or the battery of the device gets damaged then contact nearby 
authorized distributor or call to our customer care on +447411139760.

This limited warranty shall only apply to defects that are reported to the Distributor from 
whom the Customer purchased the product within the applicable warranty period. If there is 
not a Distributor, you must contact Camex Wellness Limited directly.

20. Device foot pads and foot intensity

The device should be charged for at least 6 hours before first use. 

NOTE: It is recommended to not use Circulator (Nerve & Muscle Stimulator) for more than 2 
sessions of 30 minutes (or the equivalent) per day.

21. Spillage of liquid 

The equipment is not protected against liquid ingress. Spillage of liquids which may bring live 
parts of the equipment into contact with conductive enclosures or direct contact with 
operator, other personnel or the patient, must be prevented. It’s recommended to not use the 
device around any kind of water of particulate matter. Same information is also provided in 
the caution section. IP rating of the Circulator (Nerve & Muscle Stimulator) device is IP20.

22. Technical data  

Standard and regulation

18. Batteries

Battery Handling and Usage to prevent the risk of overheating, fire or explosion: •Do not 

puncture, crush, disassemble or modify the device.

Do not throw the device into fire.

Do not recharge, use, or leave the device in any high temperature environment such as in a 

location near a fire or in direct sunlight. The device contains a built-in rechargeable 

Lithium-Ion battery which must be disposed of properly. Dispose of the device according 

to applicable local government regulations. Do not disassemble the device by yourself.

The device contains a built-in rechargeable Lithium-Ion battery which must be disposed 

of properly. Dispose of the device according to applicable local government regulations. 

Do not disassemble the device by yourself.

The system is developed and manufactured with observance of a number of directives, 

regulations and standards. Information regarding the compliance status with relevant 

national and international standards, regulations and laws can be obtained on request 

from your Camex Wellness Limited’s representative.

The system conforms to IEC 60601-1 3rd edition, ordinary equipment (enclosed without 

protection against ingress of water).

Содержание CIRCULATOR

Страница 1: ...16 Plot Number Sector 2 Akshar Industrial Park Opp Zydus Cadila Pharma Sarkhej Bavla National Highway Moriaya Ahmedabad 382213 Gujarat India Manufactured For COMFORT CLICK LIMITED Number 7 Doctor Cro...

Страница 2: ...ation 9 Care Cleaning and maintenance 10 Purchasing consumables 11 Expected service life 12 Disposal of product WEEE 13 Troubleshooting 14 EMC and Electrical standard requirement 8 9 10 11 11 11 12 13...

Страница 3: ...irculation To relieve neuropathy pain osteoarthritic pain acute and chronic body pain varicose vein To provide paralytic nervous activation For strengthening body muscle and relieve body muscle pain F...

Страница 4: ...ef by exciting sensory nerves and thereby stimulating either the pain gate mechanism and or the opioid system The type of stimulation delivered by the TENS unit aims to excite stimulate the sensory ne...

Страница 5: ...ulation over neck there is a chance that using the electrode patches on neck may cause the closure of airway dif culty in breathing Stimulation over the neck could adversely impact hearing or blood pr...

Страница 6: ...cables periodically damage Do not spill liquid or water on the device Do not use this device with Electrode Patches Cable Electrode Patches other than those provided by Camex Wellness Limited The per...

Страница 7: ...g with any other types of DC USB Cable may damage the device Usage of any other attachment that is not with your charger may result in electric shock or injury to people Shortening the terminal of the...

Страница 8: ...tex free Electrode patches Clean the foot pads with a wet clothe and dry cleaning brush The foot pads are latex free Circulator Nerve and muscle stimulator Do not clean the device while charging 10 Pu...

Страница 9: ...se everyone is different Electrodes patches cable broken Replace the cable Electrodes patches cable not connected properly Connect the cable properly You are using this device too frequently Keep suf...

Страница 10: ...ode patches have been over used or are dry Replace electrode patches Sensation is too strong Setting is too high Press the button to decrease the setting Sensation is too weak Sensation is too low Pre...

Страница 11: ...gress of water with harmful effects IPX8 Protection against continuous immersion in water up to 1 meter or as speci ed by user ON power General Warning Sign Country of manufacture To identify the coun...

Страница 12: ...e product within the applicable warranty period If there is not a Distributor you must contact Camex Wellness Limited directly 20 Device foot pads and foot intensity The device should be charged for a...

Страница 13: ...he device Step 2 Adjust the intensity through foot intensity level buttons Continue to increase the foot intensity at your comfort level Step 3 As the device is set on Auto Timer for 30 mins post 30 m...

Страница 14: ...es Peel off the protective membrane from the electrode patches and carefully place on the clean dry uninjured skin Step 2 Turn on the device through the power button of device Step 3 Adjust the intens...

Страница 15: ...10 seconds during the therapy in the PROG TIME display segment Information The poly fuse has been used in the devices and that is resettable We uses on board SMD 1812L150 LF150 Fuse Note Camex wellne...

Страница 16: ...on Date 20 06 2022 Document No CWL URM 04A Revision No 00 Revision Date 20 06 2022 29 30 EMS Voltage Waveform Foot Body 12 85v 8 58v Section Voltage Range Foot Body 20 120v 12 84v Section Voltage Rang...

Страница 17: ...Document No CWL URM 04A Revision No 00 Revision Date 20 06 2022 Document No CWL URM 04A Revision No 00 Revision Date 20 06 2022 31 32...

Отзывы: