User Manual Managed Switches
172
For each Rate Limited ID (1 to 16) it has be configured the maximum data rate.
Rate
Setting
Description
Factory
Default
Maximum rate in
pps
The valid rate is 0-131071 in pps.
15
3.12.3.3 ACL Configuration
This page shows the Access Control List (ACL), made up of the Access Control Entries (ACEs)
defined on this switch. Each row describes the ACE that is defined. The maximum number of ACEs
is 256 on each switch. Click on the lowest plus sign to add a new ACE to the list. The reserved ACEs
used for internal protocol (ex: Device bindin
g, Port mirroring, …), cannot be edited or deleted, the
order sequence cannot be changed and the priority is highest.
The information displayed on the page is summarized in the following table:
ACE
Indicates the ACE ID.
Ingress Port
Indicates the ingress port of the ACE.
It can be “All” (the ACE will match
all ingress ports) or “Port” (the ACE will match a specific ingress port).
Policy / Bitmask
Indicates the policy number and bitmask of the ACE.
Frame Type
Indicates the frame type of the ACE. Possible types are:
Any: The ACE will match any frame type.
Ethernet Type: The ACE will match Ethernet type frames. Note that an
Ethernet Type based ACE will not get matched by IP and ARP frames.
ARP: The ACE will match only ARP/RARP frames.
IPv4: The ACE will match all IPv4 frames.