User Manual Managed Switches
53
Transmission Time
Setting
Description
Factory
Default
1 to 10 (sec)
The interval between each loop protection PDU sent
on each port.
5 (sec)
Shutdown Time
Setting
Description
Factory
Default
0 to 604800 (sec)
The period (in seconds) for which a port will be kept
disabled when a loop is detected (shutting down the
port). A value of zero will keep a port disabled
permanently (until the device is restarted). The
maximum value is 604800 seconds (7 days).
180 (sec)
Port Configuration
Enable
Setting
Description
Factory
Default
Check / Uncheck
Controls whether loop protection is enabled in this
port. It is also necessary to enable the function in the
General Setting section.
Checked
Action
Setting
Description
Factory
Default
Shutdown Port /
Shutdown Port
and Log / Log
Only
Configures the action performed when a loop is
detected on a port. It is possible to disable the port
(shutdown), to log an event only or to take both
actions (shutdown and log).
Shutdown Port
Tx Mode
Setting
Description
Factory
Default
Enable / Disable
Controls whether the port is actively generating loop
protection PDUs (Enable) or whether it is just
passively looking for looped PDUs (Disable).
Enable
3.4.3.2 Status
This page displays the loop protection port status of the switch.