![Wega MyConcept EVDP 2GR Скачать руководство пользователя страница 69](http://html.mh-extra.com/html/wega/myconcept-evdp-2gr/myconcept-evdp-2gr_use-and-maintenance-manual_950832069.webp)
69
of
76
TECHNICIANS manual
ENGLISH
18.
PARAMETER TABLE
Par.
Description
min
Def
MAX
Um
P1
Temperature measurement unit 0 = °C 1 = °F
°C
°C
°F
-
P2
Pressure measurement unit 0= bar 1=Atm 2=kPa
0
0
2
P3
Volume measurement unit 0 = liters, 1 = gallons
0
0
1
P4
Number of groups present
1
3
4
-
P5
User interface language
0
0
50
N/A
P6
Cup-warmer operation enabling
0
1
1
0 = disabled.
1 = enabled.
P7
Presence of service boiler pressure transducer:
0
1
1
N/A
0 = Absent.
1 = Present.
P8
Enabling hot water dispensing together with the
coffee.
0
1
1
N/A
0 = disabled.
1 = enabled.
P9
Enable long coffee selections.
0
1
1
N/A
0 = disabled.
1 = enabled.
P10
Enable pre-infusion.
0
0
1
N/A
0 = disabled.
1 = enabled.
P11
Autosteamer activation
0
0
1
N/A
0 = disabled.
1 = enabled.
2 = enabled with automatic cleaning
P12
Enabling of automatic washing
0
0
1
N/A
0 = disabled.
1 = enabled.
P13
Enabling of initial washing
0
0
1
N/A
0 = disabled.
1 = enabled.
P14
Enabling of connection with the cash register
0
0
2
N/A
0 = No connection with the cash register.
1 = First pay mode (CREDIT - DEBIT)
2 = First dispensing mode (CREDIT - DEBIT)
P15
Enable continuous coffee dispensing
0
1
2
N/A
0 = Stop Start button disabled
1 = Stop Start button enabled
2 = Start Stop button ON for 3 sec. (Purge)
P16
Automatic daylight saving time management
0
1
2
N/A
0=Manual management
1 = Daylight saving time according to European rules
2 = Daylight saving time according to USA rules
P17
User interface theme
0
1
3
N/A
P18
Disable buzzer sound when pressing LCD keys
0
0
1
N/A
0 = Buzzer operates normally
1 = Buzzer excluded
P19
Relevant time zone
0
2
37
N/A
P20
Minimum group temperature for group 1 dispensing
60
80
105
°C
Par.
Description
min
Def
MAX
Um
P21
Minimum coffee boiler temperature for group 1
dispensing
60
80
110
°C
P22
Group 1 Temperature set
P62
93
P63
°C
P23
Group 1 coffee boiler Temperature set
P60
93
P61
°C
P24
Minimum Temperature set in group 1 standby
0
60
75
°C
P25
Minimum Temperature set in group 1 coffee boiler
standby
0
60
75
°C
P26
Temperature Delta set in group 1 standby
0
0
50
°C
P27
Minimum Temperature set in group 1 coffee boiler
standby
0
20
50
°C
P30
Minimum group temperature for group 2 dispensing
60
80
105
°C
P31
Minimum coffee boiler temperature for group 2
dispensing
60
80
110
°C
P32
Group 2 Temperature set
P62
93
P63
°C
P33
Group 2 coffee boiler Temperature set
P60
93
P61
°C
P34
Minimum Temperature set in group 2 standby
0
60
75
°C
P35
Minimum Temperature set in group 2 coffee boiler
standby
0
60
75
°C
P36
Temperature Delta set in group 2 standby
0
0
50
°C
P37
Minimum Temperature set in group 2 coffee boiler
standby
0
20
50
°C
P40
Minimum group temperature for group 3 dispensing
60
80
105
°C
P41
Minimum coffee boiler temperature for group 3
dispensing
60
80
110
°C
P42
Group 3 Temperature set
P62
93
P63
°C
P43
Group 3 coffee boiler Temperature set
P60
93
P61
°C
P44
Minimum Temperature set in group 3 standby
0
60
75
°C
P45
Minimum Temperature set in group 3 coffee boiler
standby
0
60
75
°C
P46
Temperature Delta set in group 3 standby
0
0
50
°C
P47
Minimum Temperature set in group 3 coffee boiler
standby
0
20
50
°C
P50
Minimum group temperature for group 4 dispensing
60
80
105
°C
P51
Minimum coffee boiler temperature for group 4
dispensing
60
80
110
°C
P52
Group 4 Temperature set
P62
93
P63
°C
P53
Group 4 coffee boiler Temperature set
P60
93
P61
°C
P54
Minimum Temperature set in group 4 standby
0
60
75
°C
P55
Minimum Temperature set in group 4 coffee boiler
standby
0
60
75
°C
P56
Temperature Delta set in group 4 standby
0
0
50
°C
P57
Minimum Temperature set in group 4 coffee boiler
standby
0
20
50
°C
P60
Coffee boiler minimum temperature.
0
60
P61
°C
P61
Coffee boiler maximum temperature.
P60
110
120
°C
P62
Group minimum temperature.
0
60
P63
°C
P63
Group maximum temperature.
P62
105
120
°C
P65
On time solenoid valve group during pre-infusion.
0
0.5
10
S
P66
Off time solenoid valve group during pre-infusion.
0
1.5
10
S
P67
Coffee boiler full recognition pressure (machines
with analog pressure transducer in coffee boilers).
0.1
2
6
bar
P68
Group SV opening time during the coffee boiler filling
phase for air evacuation.
0
10
20
s
P69
Delay due to closure of all the group solenoid valves
in the initial loading stage.
0
2
20
s
P70
Group heating timeout. (P-band input)
0
45
255
Min
P71
Coffee boiler heating timeout. (P-band input)
0
45
255
Min