![Wega MyConcept EVDP 2GR Скачать руководство пользователя страница 65](http://html.mh-extra.com/html/wega/myconcept-evdp-2gr/myconcept-evdp-2gr_use-and-maintenance-manual_950832065.webp)
65
of
76
TECHNICIANS manual
ENGLISH
Fuse
Description
F1
Fuse 5x20 delayed, 6.3A
Protects: from RL1 to RL13
F2
Fuse 5x20 FF super rapid, 10A
Protects: group coffee boiler heating element 4
F3
Fuse 5x20 FF super rapid, 10A
Protects: group coffee boiler heating element 2
F4
Fuse 5x20 FF super rapid, 10A
Protects: group coffee boiler heating element 3
F5
Fuse 5x20 FF super rapid, 10A
Protects: group coffee boiler heating element 1
F6
Fuse 5x20 FF super rapid, 10A
Protects : coffee boiler heating elements, group 1 and 3
F7
Fuse 5x20 delayed, 1A
Protects: transformer's double winding
F8
Fuse 5x20 FF super rapid, 10A
Protects : coffee boiler heating element group 2 and 4
F9
Fuse 5x20 delayed, 1A
Protects: services boiler heating element group 1 and 2
F11 Fuse 5x20 delayed, 125mA
Protects: trans12Vac
LED
Description
DL1
Front Led
DL2
Side Led
DL3
Cup heater
DL4
Heating element control boiler group 4
DL5
Heating element control boiler group 2
DL6
Heating element control boiler group 3
DL7
Heating element control boiler group 1
DL8
group 1 heating element
DL9
group 3 heating element
DL10
group 2 heating element
DL11
group 4 heating element
DL12
services 1 boiler heating element
DL13
group 4 volumetric counter
DL14
group 3 volumetric counter
DL15
group 2 volumetric counter
DL16
group 1 volumetric counter
DL17
services 2 boiler heating element
DL18
Inlet volumetric counter
DL20
CN45 connection
DL21
Display connection
DL22
Display connection
DL23
Communication RS232 CN13
+5V
+5V Power supply
+9V
+9V Power supply
+12V
+12V Power supply
+24V
+24V Power supply
Relay Description
RL1
Pump
RL2
Solenoid valve group 1
RL3
Solenoid valve group 3
RL4
Solenoid valve group 2
RL5
Solenoid valve group 4
RL6
Boiler filling solenoid valve
RL7
Hot water mix solenoid valve
RL8
Tea solenoid valve 1
RL9
Autosteamer steam solenoid valve
RL10
Side LED solenoid valve
RL11
Air solenoid valve
RL12
Tea solenoid valve 2
RL13
Front LED solenoid valve
Conn. Description
CN1
Heating element connection 1 - 3 GR
CN2
Heating element connection 2 - 4 GR
CN3
Services boiler heating element connection
CN4
Connection of coffee boiler pressure switches
CN5
Volumetric dispenser and services boiler level connection
CN13
RS232 serial socket connection
CN15
Coffee boiler pressure NTC connection
CN16
Mains pressure, humidity sensor and boiler press. transducer supply
CN17
Connection of NTC services boiler
CN18
Connection of NTC Autosteamer
CN19
Connection of NTC cup heater
CN22
Wiring of circuit board
CN23
Connection of 230V AC outputs
CN24
Connection of 230V AC outputs
CN25
Boiler heating element connection 2 - 4 GR
CN26
Boiler heating element connection 1 - 3 GR
CN41
Display TFT cable connection
CN42
Level probe connection.
CN43
WiFi module connection
CN45
Not used.
CN46
USB drive connection
Jumper Description
SW3
Micro factory programming
SW5
485 CN45 activation not used
JP6
Serial power management: 1-2=+12V 2-3=+5V