Wealtec CB-1 Скачать руководство пользователя страница 3

Block Cooler V1.0 

  1

A. Important Notice

 

 

Before setting up and operating the instruments of Block Cooler (CB-1) system, please 

carefully read these instructions to get familiarized with the installation and operation process. 

Instructions should be read by experienced individuals before operating the instruments.     

Any improper usage of the instruments may cause damage. Please refer to the safety 

notice included with this equipment. 

The instruments shall not be modified or altered in any way. Any modification or alteration 

will void the warranty, void the regulatory certifications and create potential safety hazard. 

Wealtec is not responsible for any injury or damage caused by using the instruments for any 

non-intended purpose or injury as a result of modification of the instruments by any person who 

is not authorized by Wealtec Corp.   

 

A-1. Warranty 

 

Block Cooler system is warranted to be free from defects in materials or workmanship for a 

period of one year from the original invoice date, under normal usage. Any defects occurring 

during warranty period, Wealtec Corp. will repair or replace defective products or parts without 

charge unless the defects arise from conditions outlined below. The defects described below are 

specially excluded from Wealtec warranty policy.   

1.  Improper operation of the instrument. 

2.  Repair or modification by any person who is not authorized by Wealtec Corp.   

3.  Damage caused by any (in)-direct accident, neglect or misuse. 

4.  Damage caused by disaster.   

5.  Damage caused by any improper solvents or samples 

 

A-2. Technical and Service Contact 

 

Most of the operation details are described in this instruction manual to assist and guide 

operator for an appropriate solution. For any other technical/ service questions, please contact 

your local representative or contact Wealtec international technical/ service specialist by E-mail: 

[email protected]

 

Содержание CB-1

Страница 1: ...Block Cooler System CB 1 Installation and Operation Manual Version 1 0 Item 03060 This instrument is intended for laboratory use only...

Страница 2: ...pecifications B 2 Product Description B 2 1 Block Cooler System Hardware Overview C Installation of Block Cooler System CB 1 9 C 1 Package List C 2 Installation of Block Cooler System C 2 1 Installati...

Страница 3: ...rp A 1 Warranty Block Cooler system is warranted to be free from defects in materials or workmanship for a period of one year from the original invoice date under normal usage Any defects occurring du...

Страница 4: ...tion Do not apply more or lower than the rated voltage specified on the instrument or it may cause damages to the instrument Do not splash water or liquid onto the block cooler system the spilled wate...

Страница 5: ...ded Applications 0 C Replace the ice buckets for samples enzymes storage 4 C Sample cooling storage during operation i e Store nucleic acid at 4 C in long PCR at final stage DNA purification kit rinsi...

Страница 6: ...etry of Apoptosis Incubate the plug at 37 C in Pulsed Field Gel Electrophoresis For gel digestion pre treatment before MALDI TOF MS analysis 42 C The reverse transcription temperature by RT PCR Enzyme...

Страница 7: ...rose dissolving Denatured sample i e Pre heating protein molecules before SDS PAGE running Customize Temperature Between 0 75 C Specific incubation temperatures for chemistry molecular biology experim...

Страница 8: ...Block capacity 1 Operating conditions Temperature 0 26 Humidity 10 to 90 R H Non condensing Aluminum block Block type 48 Well aluminum block Well type 8 x 0 2 ml 21 x 0 5 ml 15 x 1 5 ml 4 x 2 0 ml Nu...

Страница 9: ...Press this button and adjust the offset value in order to alter the temperature of the block cooler system to the desired temperature as per to users Process indicator Power switch Protection lid Pro...

Страница 10: ...ressing to the desired temperature Up and down key is used to adjust the desired temperature value and the desired mode of the temperature LCD display Displays the temperature value and the mode setti...

Страница 11: ...Block Cooler V1 0 9 C Installation of Block Cooler System CB 1 C 1 Package List Item Quantity Block cooler system CB 1 1 48 Well aluminum block 1 Block protection rubber 1 Block extractor 1...

Страница 12: ...with the minimum size of 200mm L x 304mm W x 184mm H 7 87 x 11 97 x 7 24 2 Place the 48 well aluminum block into the block cooler system and place the block protection rubber on top of the block 3 Th...

Страница 13: ...setting the temperature parameter press Run Stop key once to start running the block cooler Note In general the block cooler system will require several minutes to achieve the desired temperature on...

Страница 14: ...y thermometer is not calibrated accordingly to international standard thermometer Some temperature variation may occur with the usage of the different non calibrated thermometers Caution Maximum adjus...

Страница 15: ...e system achieves the desired temperature 4 and stabilized Ready indicator turned on h When the ready indicator turned on ensure the temperature reading on the users calibrated thermometer is as per t...

Страница 16: ...tion Fan is not spinning LED Display do not light up Front panel power on indicator off Check main AC power source Replace a new same configuration fuse and try again Check if power switch malfunction...

Страница 17: ...ntative Overheat Error The block cooler system is overheated during a run temperature of the system exceeded more than 100 C Ensure the block cooler system operating condition temperature 0 26 Contact...

Страница 18: ...lean water Organic solvents or strong detergents may damage the instrument and should not be used 48 Well aluminum block should be protected from organic solvents and detergents and it should be clean...

Страница 19: ...ption 1093001 CB 1 Block Cooler System with block extractor 48 well aluminum block and block protection rubber 100 240VAC 50 60Hz Optional Accessories Item Description 1093101 48 Well aluminum block f...

Страница 20: ...03060 Wealtec Corp 1885 Meadowvale Way Sparks NV 89431 Tel 1 775 351 2066 Fax 1 775 351 2077 http www wealtec com E mail support wealtec com...

Отзывы: