Operation manual Soldos - SL (04-09) page 16 of 18
9. Maintenance
Please consider:
- Change the dosing hose of the peristaltic pump yearly.
- Check the pump head with the roller always when you exchange the
brine bag. Check if there´s corrosion or other signs of wear. The rollers
have to be even and must not show grooving.
- Check the hose connections if they are seal.
- Check and clean the air filter of the compressor monthly.
When the unit is taken out of operation we recommend a flushing of the
whole system with distilled water, to prevent incrustations. Afterward take
out the roller of the pump head to discharge the dosing hose.
When the unit is taken into operation again we recommend to do a
disinfection.
Tap water contents calcium that would block the very fine boring
of the nozzle
Maintenance of the rooms
The interior of the room has to be cleaned out with a wet towel at the end
of a day, so no deposits or incrustations will come up.