Operation manual Soldos - SL (04-09) page 14 of 18
This procedure complies with the Ö-Norm 6222 part 1.
The Soldos is securely disinfected.
Flushing:
Step 5:
Remove the canister (with disinfection solution) and draw
the new brine canister with germfree brine solution. Turn
the programme switch to “flushing”. Now, the brine
solution is dosing for 4 minutes in order to completely
flush out the disinfection concentration.
Step 5.1
After the rinsing process, the dosing performance of the hose
pump has to be reseted to the performance before the
disinfection process.
Step 6:
Remove the PVC compact (with the PE downpipe hose) from the nozzle.
The Soldos is ready for operation again, when the programme switch is turned
back to the initial position.
Step 7:
Every disinfection has to be written down in the following protocol.
Durability
On every canister, the expiration date is stated. Furthermore, every canister
should be consumed within 4 weeks after opening.