Operation manual Soldos - SL (04-09) page 11 of 18
When the unit is taken into operation we recommend to set the spraying-
and pause time on a medium setting (Pause time 4 minutes, Spraying
time 25 seconds, Dosing time peristaltic pump app. 1,6l with hose 3,2).
On the basis of these values the settings have to be adapted to the
situation on site and the demanded salt intensity by trial.
For taking the unit into operation the unit has to be switched on with the
main-switch in the right side of the control housing.
6.3 Settings
The single operation parameters can be adjusted at the front plate of the
SOLDOS-SL.
Dosing performance in l/h during continous operation:
This stepless Poti is to set the dosing performance of the peristaltic brine
pump in l/h. Due to tolerances of some components of the rpm-control and
the dosing hose the effective dosing performance can vary +/- 15% of the
adjusted dosing performance.
Pause time in minutes:
Pause time in between the nebulisation intervals.
Spraying time in seconds:
This rotary knob is to set how long the spraying shall last. During this time
the peristaltic pump and the compressor works.
Attention: After the spraying time the follow-up time of 10 seconds of the
compressor is activated (see page 4).