background image

ColorFlat7 RGB

wdmlighting.com | 4106 Harry Hines Blvd, Dallas, Texas 75219 | 800-893-9787

Page 3

 

ColorFlat 7 RGBW/RGBW

 

Copyright (c) 2011  WDM Lighting

 

   

1. GETTING STARTED

 

   

What’s In The Box?

 

   

• 1 x 

ColorFlat

™ 

Flat LED PAR Fixture

 

• 1x IEC Power Cord

 

• User Manual

 

   

   

Getting It Out Of The Box

 

   

Now that you’ve got The 

ColorFlat

™ 

,  you should carefully unpack  the 

box and check the contents  to ensure that all parts are present  and in 

good condition.  If anything  looks as if it has been dam- aged in transit, 

notify the shipper  immediately  and keep the packing material  for 

inspection.   Again, please save the carton and all packing materials.  If 

a fixture must be returned  to the factory,  it is important that the 

fixture be returned  in the original  factory box and packing.

 

   

Powering Up!

 

   

All fixtures  must  be powered  directly  off a switched  circuit  and cannot 

be run off a rheostat  (variable  resistor)  or dimmer  circuit,  even 

if the rheostat  or dimmer  channel  is used solely for a 0% to

 

100% switch.

 

   

AC Voltage  Switch - Not all fixtures  have a voltage  select switch, so 

please verify that the fixture you receive  is suitable  for your local  

power supply.   See the label on the fixture or refer to the fixture’s 

specifications chart for more information.   A fixture’s  listed current 

rating is its average  current  draw under normal conditions.  Check the 

fixture or device carefully  to make sure that if a voltage  selection 

switch exists that it is set to the correct line voltage  you will use.

 

   

   

Warning!  Verify that the voltage  select switch on your unit 

matches  the line voltage  applied.  Damage  to your fixture may 

result if the line voltage  applied  does not match the voltage 

indicated  on the voltage  selector  switch.  All fixtures must be 

connected  to circuits  with a suitable  Ground  (Earthing).

 

   

ColorFlat7 RGB

wdmlighting.com | 4106 Harry Hines Blvd, Dallas, Texas 75219 | 800-893-9787

Содержание ColorFlat7 RGB

Страница 1: ...ColorFlat7 RGB wdmlighting com 4106 Harry Hines Blvd Dallas Texas 75219 800 893 9787 ColorFlat 7 RGBW RGBA ...

Страница 2: ... Can 5 Features 5 DMX Quick Reference 4 and 6 Channel Modes 5 The ColorFlat 7 6 3 Setup 7 Fuse Replacement 7 Connecting ColorFlat 7 LED PAR Cans 7 Data DMX Cables 7 4 Operating Adjustments 8 DMX Mode DMX Mode Selection 8 Master Slave Mode 8 Sound Active Mode 8 Custom Color Display 8 Fixture running hour display 8 Troubleshooting 9 5 Appendix 10 Maintenance 10 Returns 10 Shipping Issues 10 Tech Spe...

Страница 3: ...rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch AC Voltage Switch Not all fixtures have a voltage select switch so please verify that the fixture you receive is suitable for your local power supply See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current ratin...

Страница 4: ...ts are blocked ALWAYS disconnect from the power source before servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT operate at ambient temperatures higher than 104 F 40 C In the event of a serious operating problem stop using the unit immediately NEVER try to rep...

Страница 5: ...ter slave Built in sound active programs ADDITIONAL FEATURES Lightweight and Compact 4 Button LED control panel for easy programming Light source 7 x 9 Watt LEDs Tri Color or 7 x 3 Watt LEDs Dual bracket for flexibility in mounting Power outlet for fixture linking up to 10 fixtures DMX Quick Reference 6 Channel Mode Channel What It Does 1 Red Intensity 2 Green Intensity 3 Blue Intensity 4 Built in...

Страница 6: ...lat 7 RGBW RGBW ColorFlat 7 RGBW RGBW Rev A Copyright c 2011 Blizzard Lighting LLC Figure 1 The ColorFlat 7Pin Up Picture Dual Mounting Yokes Figure 2 The Rear Connections Quad Color LED s DMX In DMX Out LED Control Panel AC Power In Out Microphone ColorFlat7 RGB ColorFlat 7 RGBW RGBA Tri Color LEDs ...

Страница 7: ...le line Also connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run distance is 500 meters 1640 ft The maximum recommended number of fixtures on a serial data link is 32 fixtures Data DMX Cabling To link fixtures together you ll need data cables You should ...

Страница 8: ...its together using DMX cable Master SLNd then NASt to confirm 3 Select slave function by using the UP DOWN keys to reach SLAV in the Master Auto menu on the slave units and they will react in the same as the Master Slave SLNd then SLAu to confirm 4 On the master fixture use the UP DOWN keys to reach SHND which allows you to select the Master Slave mode Sound active SoUn then ENTER to confirm Auto ...

Страница 9: ...ck fuse AC cord and circuit for malfunction Blown Fuse Check AC cord and circuit for damage verify that moving parts are not restricted and that unit s ventilation is not obstructed Slow Movement Verify that 220V 110V switch is in the correct position if applicable Also check that speed channels are set appropriately No Response to Audio Verify that the fixture is in Sound Active mode Adjust Audio...

Страница 10: ...att Light Source LED 7 x 9 Watt TriColor LED s 60K hrs 7 x 3 Watt TriColor LED s 60K hrs Optical Beam Angle 25 degrees Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Control Protocol USITT DMX 512 DMX Channels 4 or 6 User Selectable Input 3 pin XLR Male Output 3 pin XLR Female Other Operating Modes Standalone Master Slave Sound Active Color Preset Standalone color mixing Warranty 2 ...

Отзывы: