3. SETUP

 

 

   

   

   

Fuse Replacement

 

   

With a flat head screwdriver,  wedge the 

fuse holder out of its housing.  Remove  the 

damaged  fuse from its holder and replace 

with exact same type fuse. Insert the fuse 

holder back in its place and reconnect 

power.

 

   

Connecting  A Bunch of ColorFlat 7Flat LED PAR Cans

 

   

You will need a serial data link to run light shows using a DMX-512 

controller  or to run shows on two or more fixtures  set to sync in mas- 

ter/slave  operating  mode. The combined  number  of channels  required 

by all the fixtures  on a serial data link determines  the number  of fix- 

tures the data link can support.

 

   

Fixtures  on a serial  data link must  be daisy  chained  in one single  line. 

Also,  connecting  more  than 32 fixtures  on one serial  data link without 

the use of a DMX  optically-isolated  splitter  may  result  in deterioration 

of the digital DMX signal.

 

The maximum  recommended  cable-run  distance  is 500  meters  (1640 

ft).  The maximum  recommended  number  of fixtures  on a serial  data 

link is 32 fixtures.

 

   

Data/DMX  Cabling

 

   

To link fixtures  together  you’ll need data cables.   You should  use data- 

grade  cables  that can carry  a high  quality  signal  and are less prone  to 

electromagnetic  interference.

 

   

For instance,  Belden©  9841 meets the specifications  for EIA RS-485 

applications.  Standard  microphone  cables will “probably”  be OK, but 

note that they cannot transmit  DMX data as reliably  over long distanc- 

es.  In any event, the cable should have the following  characteristics:

 

   

2-conductor  twisted  pair plus a shield

 

Maximum  capacitance  between  conductors  – 30 pF/ft. 

Maximum  capacitance  between  conductor  & shield – 55 pF/ft. 

Maximum  resistance  of 20 ohms / 1000 ft.

 

Nominal  impedance  100 – 140 ohms

 

ColorFlat7 RGB

Содержание ColorFlat7 RGB

Страница 1: ...ColorFlat7 RGB wdmlighting com 4106 Harry Hines Blvd Dallas Texas 75219 800 893 9787 ColorFlat 7 RGBW RGBA ...

Страница 2: ... Can 5 Features 5 DMX Quick Reference 4 and 6 Channel Modes 5 The ColorFlat 7 6 3 Setup 7 Fuse Replacement 7 Connecting ColorFlat 7 LED PAR Cans 7 Data DMX Cables 7 4 Operating Adjustments 8 DMX Mode DMX Mode Selection 8 Master Slave Mode 8 Sound Active Mode 8 Custom Color Display 8 Fixture running hour display 8 Troubleshooting 9 5 Appendix 10 Maintenance 10 Returns 10 Shipping Issues 10 Tech Spe...

Страница 3: ...rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch AC Voltage Switch Not all fixtures have a voltage select switch so please verify that the fixture you receive is suitable for your local power supply See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current ratin...

Страница 4: ...ts are blocked ALWAYS disconnect from the power source before servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT operate at ambient temperatures higher than 104 F 40 C In the event of a serious operating problem stop using the unit immediately NEVER try to rep...

Страница 5: ...ter slave Built in sound active programs ADDITIONAL FEATURES Lightweight and Compact 4 Button LED control panel for easy programming Light source 7 x 9 Watt LEDs Tri Color or 7 x 3 Watt LEDs Dual bracket for flexibility in mounting Power outlet for fixture linking up to 10 fixtures DMX Quick Reference 6 Channel Mode Channel What It Does 1 Red Intensity 2 Green Intensity 3 Blue Intensity 4 Built in...

Страница 6: ...lat 7 RGBW RGBW ColorFlat 7 RGBW RGBW Rev A Copyright c 2011 Blizzard Lighting LLC Figure 1 The ColorFlat 7Pin Up Picture Dual Mounting Yokes Figure 2 The Rear Connections Quad Color LED s DMX In DMX Out LED Control Panel AC Power In Out Microphone ColorFlat7 RGB ColorFlat 7 RGBW RGBA Tri Color LEDs ...

Страница 7: ...le line Also connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run distance is 500 meters 1640 ft The maximum recommended number of fixtures on a serial data link is 32 fixtures Data DMX Cabling To link fixtures together you ll need data cables You should ...

Страница 8: ...its together using DMX cable Master SLNd then NASt to confirm 3 Select slave function by using the UP DOWN keys to reach SLAV in the Master Auto menu on the slave units and they will react in the same as the Master Slave SLNd then SLAu to confirm 4 On the master fixture use the UP DOWN keys to reach SHND which allows you to select the Master Slave mode Sound active SoUn then ENTER to confirm Auto ...

Страница 9: ...ck fuse AC cord and circuit for malfunction Blown Fuse Check AC cord and circuit for damage verify that moving parts are not restricted and that unit s ventilation is not obstructed Slow Movement Verify that 220V 110V switch is in the correct position if applicable Also check that speed channels are set appropriately No Response to Audio Verify that the fixture is in Sound Active mode Adjust Audio...

Страница 10: ...att Light Source LED 7 x 9 Watt TriColor LED s 60K hrs 7 x 3 Watt TriColor LED s 60K hrs Optical Beam Angle 25 degrees Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Control Protocol USITT DMX 512 DMX Channels 4 or 6 User Selectable Input 3 pin XLR Male Output 3 pin XLR Female Other Operating Modes Standalone Master Slave Sound Active Color Preset Standalone color mixing Warranty 2 ...

Отзывы: