Operating Instructions and Parts Manual
www.waynepumps.com
2
rmation visit
www.waynepumps.com
2.
Battery sizes that will fit into the battery box are 24C, 24VCM, 27C, 27CM, and 27F.
3.
Battery recharge time will be different at each installation. Under normal conditions it will
take two to four days to bring a deep cycle battery back to full charge after it has been
discharged. If electrical power to the house is lost more than once a week, consider keeping
a spare, fully-charged battery to replace an exhausted battery for the back-up sump pump.
Installation
–
ESP15
Installation of this
unit may take
several hours. Before disabling your main pump, have ready an appropriate means of evacuating the
sump.
1. Turn power to main pump off.
2. Pump must be installed using 1-1/4 in. or 1-1/2 in. rigid PVC piping. A check valve (not
included) must be installed between the ESP’s tee and the main pump (see Figure 1).
LEAVE A 4 IN.
MIN. BETWEEN
BASIN LID
AND
BACK-UP
PUMP
CHECK
LEAVE A 1 IN.
VALVE
MIN. BETWEEN
BACK-UP AND
PRIMARY PUMP
Figure 1
3.
Measure and cut discharge pipe so that back-up pump is a minimum of 1 in. above the main
pump. This will allow main pump to operate normally (see Figure 1).
4.
Check the fit of the components
before permanently attaching. Using
354001-001 7/11
Installation - ESP15
(continued)
5. Insert flapper valve into tee. Be sure locator
tab is in the notch of the tee fitting (see
Figure 2).
hole, and secure with nut. Make sure
that float switch is above pump base and
that power wires do not interfere with
float switch or pump inlet.
Installation
–
ESP25
I
n
s
t
a
l
l
a
t
i
o
n
o
f
t
h
i
s
u
n
i
t
m
a
y
t
a
k
e
several hours. Before disabling your main pump,
have ready an appropriate means of evacuating
the sump.
1. Turn power to main pump off.
Do NOT
use to
deep cycle battery. Electrolyte level
PVC cement, glue tee in place. Note must be
checked and maintained
the up direction arrow on the tee; the
in accordance with manufacturer’s
notch must be to the top or flapper guidelines.
valve will not work (see Figure 2).
pump flammable or explosive
fluids such as
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual
or file it for safekeeping.
6.
Slide clamp onto tee.
7.
Insert pump into flapper valve, tilt pump 30˚.
When tilted, the side with
The ESP25 can be installed as a back-up
system with a separate dedicated discharge
line (Method 1), or tied into an existing sump
pump line (Method 2, Page 3).