background image

© 2009 Wayne Water Systems

330102-001 2/09

Effluent 

Pump

Operating Instructions and Parts Manual 

Model EFL33

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. 
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or 
property damage! Retain instructions for future reference.

Description

An effluent system consists of a pump, 
control switch and a basin. The system 
is generally controlled by a float switch 
with a plug-in plug which accepts the 
pump plug and in turn plugs into a 115 
volt outlet.
The float switch is a wide angle 
differential switch that rises with 
the liquid level and turns the pump 
on. As the liquid level decreases, the 
float lowers and turns the pump 
off. This pump is intended for use in 
domestic sump or effluent lift stations. 
It is suitable for pumping effluent, 
wastewater, ground water and other 
nonexplosive, noncorrosive liquids with 
up to 3/4 inch solids.

 

Effluent pump will  

  not pump raw 

sewage or any substance exceeding  
3/4 inch size.

For parts, product & service information

visit 

www.waynepumps.com

REMINDER: Keep your dated proof of purchase for warranty purposes!  

Attach it to this manual or file it for safekeeping.

 Specifications

  Power supply requirements .............. 115V, 60 hz
  Circuit requirements .......................... 15 amps (min)
  Motor duty ......................................... Intermittent
  Motor ................................................. 115V, 1 Phase, 1725 RPM
  Horsepower  ....................................... 1/3
  Motor full load .................................. 11 amps
  Liquid temperature range ................. 40º F to 120º F
  Max. operating position .................... 45º from vertical
  Dimensions ......................................... 13-1/2 inch x 11 inch
  Intake ................................................. 2 inch
  Discharge ............................................ 2 inch NPT female, 3 inch 

NPT male

  Cut-in level (factory set) .................... 18 inch
  Cut-out level (factory set) ................. 10 inch
  Differential ......................................... 8 inch
  Switch ................................................. 90º wide angle  

mechanical tether switch

  Power cord ......................................... 16 gauge 3 conductor  

w/plug

 Construction

  Motor body material ............Cold rolled steel
  Motor housing ......................Glass reinforced  

polypropylene

  Volute ....................................Glass reinforced ABS
  Impeller .................................Glass reinforced PBT
  Seal plate ..............................Cast Iron
  Shaft seal ...............................End faced mechanical

Performance

GALLONS PER hOuR At tOtAL hEAD IN FEEt

Model

10

15

200

EFL33

3600

1300

0

unpacking

Inspect this unit before it is used. 
Occasionally, products are damaged 
during shipment. If the pump or 
components are damaged, return 
the unit to the place of purchase for 
replacement. Failure to do so could 
result in serious injury or death.

Safety Guidelines

This manual contains information 
that is very important to know and 
understand. This information is 
provided for SAFETY and to PREVENT 
EQUIPMENT PROBLEMS. To help 
recognize this information, observe the 
following symbols.

 

Danger indicates  

  an imminently 

hazardous situation which, if not 
avoided, WILL result in death or serious 
injury.

 

Warning indicates  

  a potentially 

hazardous situation which, if not 
avoided, COULD result in death or 
serious injury.
 

Caution indicates  

  a potentially 

hazardous situation which, if not 
avoided, MAY result in minor or 
moderate injury.
 

Notice indicates  

  important 

information, that if not followed, may 
cause damage to equipment.

General Safety Information

CALIFORNIA PROPOSItION 65

 

This product or its  

  power cord contains 

chemicals known to the State of 
California to cause cancer and birth 
defects or other reproductive harm. 
Wash hands after handling.

Содержание 330102-001

Страница 1: ...erating position 45 from vertical Dimensions 13 1 2 inch x 11 inch Intake 2 inch Discharge 2 inch NPT female 3 inch NPT male Cut in level factory set 18 inch Cut out level factory set 10 inch Differen...

Страница 2: ...th pad locks master switch es and by re mov ing starter keys 10 When wiring an elec tri cal ly driven pump such as this fol low all electrical and safety codes as well as the most recent National Elec...

Страница 3: ...will pass 3 4 inch solids or as required by state and local codes This gate valve permits removal of the pump and or check valve for servicing 5 A union should be installed between the check valve an...

Страница 4: ...Recheck all sizing calculations to determine proper pump size Pump shuts off and turns on independently of switch trips thermal overload protection 1 Excessive water temperature 2 Defective switch or...

Страница 5: ...ts 8 Mechanical switch kit 60022 001 1 9 Oil plug 37303 001 1 Reference Number Description Part Number Quantity Repair Parts List For replacement parts call 1 800 237 0987 Please provide following inf...

Страница 6: ...e states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the above lim i ta tions might not apply...

Страница 7: ...Dimensions 34 3 X 28 cm 13 1 2 po x 11 po Entr e 5 08 cm 2 po D charge 5 08 cm 2 po NPT femelle 7 6 cm 3 po NPT m le Niveau de d marrage r gl l usine 45 7 cm 18 po Niveau d arr t r gl l usine 25 4 cm...

Страница 8: ...t quipement apr s l usage c Garder les visiteurs une distance s re de l endroit de travail Prot ger l atelier pour les enfants avec des cadenas interrupteurs principals et en enlevant les clefs de d m...

Страница 9: ...po dans le tuyau de d charge environ 1 2 po par dessus le d charge de la pompe lorsque vous utilisez un clapet Le trou emp che le blocage par l air de la pompe au d part initial et si elle perd l amo...

Страница 10: ...liquide soit au moins 33 02 cm 13po du fond du bassin La pompe se d marre et s arr te trop souvant 1 Refoulement d eau de la tuyauterie 2 Interrupteur flotteur d fectueux 3 Clapet non install ou qui a...

Страница 11: ...le fonctionnement libre 7 Ouvrir la soupape 1 Carter de moteur 28088 001 1 2 Cordon d alimentation 31026 001 1 3 8 16 x 1 po Vis 67112 001 6 4 Joint d tanch it du carter 17456 002 1 5 Turbine 17317 0...

Страница 12: ...UE SE SOIT EST EXCLUS Certaines Provinces n autorisent pas de limitations de dur e pour les garanties implicites ni l exclusion ni la limitation des dommages fortuits ou indirects Les limitations pr c...

Страница 13: ...Salida 5 08 cm 2 inch NPT hembra 7 6 cm 3 inch NPT macho Nivel para encender fijado de f brica 45 7 cm 18 inch Nivel para apagar fijado de f brica 25 4 cm 10 inch Diferencial 20 3 cm 8 inch Interrupt...

Страница 14: ...lejados del rea de trabajo Cerci rese de tomar todas las medidas de seguridad necesarios para evitar accidentes con ni os use candados y cortacircuitos y no deje las llaves al alcance de los ni os 10...

Страница 15: ...scarga de la bomba Este orificio evita que el aire obstruya la bomba al encenderla por primera vez o cuando pierda el cebado 4 Debe instalar una v lvula de entrada inmediatamente despu s de la v lvula...

Страница 16: ...v lvula de chequeo o la v lvula de chequeo tiene una fuga 4 La distancia de la descarga es inferior al m nimo recomendado por el fabricante 1 Instale una v lvula de chequeo 2 Reemplace el interruptor...

Страница 17: ...ela a ver si est bien instalada y funcionando adecuadamente 7 Abra la v lvula 1 Cubierta del motor 28088 001 1 2 Cord n el ctrico 31026 001 1 3 Tornillo de 8 16 x 25 4 mm 1 inch 67112 001 6 4 Empaque...

Страница 18: ...lgunos estados no permiten que se establezcan l mites en la duraci n de las garant as implicitas o no permiten que se excluyan ni se establezcan l mites en los da os por incidentes o consecuencias por...

Страница 19: ...Notes Notas Notes 19 EFL33...

Страница 20: ...Notes Notas Notes EFL33 Operating Instructions and Parts Manual Instructions d Utilisation et Manual de Pi ces Manual de Instrucciones de Operaci n y Piezas 20...

Отзывы: