8
Wayne Kerr AP 1kW Power Supplies • Issue 2
4. SPECIFICATION
All parameters measured with a resistive load.
Models Available
Model Nº
P max
V range
I range
AP30-80
1kW
0-30V
0-80A
AP60-50
1kW
0-60V
0-50A
AP100-30
1kW
0-100V
0-30A
A.C Input
230V
±
14% (198 to 263V) or 115V
±
14% (99 to132V) 48 to 63Hz
Internal link and selector switch to change for 115V operation.
Input Current
9A max. r.m.s. for 240V a.c. (20A peak), 20A max. r.m.s. for 115V a.c.
Inrush Current
31A max. for 240V a.c. 16A for 115V a.c.
Efficiency
80% typical at max. output power
D.C. Output
See models available for voltage and current ranges.
10
20
30
20
40
60
80
34A
40A
50A
66.7A
80A
20
40
60
50
30
10
10
20
30
40
50
16.7A
20A
25A
33.5A
40A
50A
100
80
60
40
20
10A
12.5A
16.7A
20A
25A
30A
10
20
30
34
Fig. 4a. AP3080
Fig. 4b AP 6050
Fig. 4c. AP10030
Output Control
Three methods of control:
1. Front panel ten turn potentiometers.
2. Remote programming by resistance, voltage or current.
3. IEEE488 bus control
Resolution of Controls
0.07% typical of max. output voltage.
0.07% typical of max. output current.
Line Regulation
For a 10% change of a.c. input from
nominal
Less than 0.01% +3mV in constant voltage (CV) mode.
Less than 0.01% +5mA in constant current (CI) mode.
Load Regulation
For a zero to full load change
Less than ±0.01% ±5mV in CV mode.
Less than ±0.01% ±5mA in CI mode.
Содержание AP10030
Страница 63: ...AP 1kW Power Supplies Issue 2 Circuit Diagrams Page 63...
Страница 64: ...AP 1kW Power Supplies Issue 2 Circuit Diagrams Page 64...
Страница 65: ...AP 1kW Power Supplies Issue 2 Circuit Diagrams Page 65...
Страница 66: ......
Страница 67: ......
Страница 68: ......
Страница 69: ......
Страница 70: ......