Wayne Kerr AP10030 Скачать руководство пользователя страница 51

AP 1kW Power Supplies • Issue 2 

 

Page 51 

Part No 

Description 

Iss  Qty  Man 

Man Part No 

Reference 

RF16R02NJ 

6R0 + 6R0  (DUAL) 5%  11W0 

 

17V 

226-216 

R301 

SR20016 

HI V POWER 12VDC 16AAC DPNO 

 

16J 

REP200/12V+D.C.+4KV 

RL301 

WF3M 

FLAT WASHER M3 

 

05T 

WF3M 

 

WF4M 

FLAT WASHER M4 

 

05T 

WF4M 

 

WS3M 

SPRING WASHER M3 

 

05T 

WS3M 

 

WS4M 

SPRING WASHER M4 

 

05T 

WS4M 

 

YT18 

T/C WIRE 18SWG 

 

.062  55M 

18SWG 

 

5N6050IP 

I/P FILTER CB  

A  

 

 

BC238 

FILTER 60/50'S           

01K 

2BS23B2380 

CAOMIT 

CAPACITORS OMITTED 

 

00F 

CAOMIT 

C312 3 

CX6470NPM 

470NF   20%  250V        R250 

 

13R 

PME+271M647 

C303 5 6 9:10 

CXA1U00PM 

1.0UF   20%  250V        R275 

 

13R 

PHE+830MF7100M 

C304 

CY42N20PM 

2.2NF   20%  250V        R100 

 

13R 

PME+271Y422M 

C301 2 

CY522N0PM 

22NF    20%  250V        R150 

 

13R 

PME+271Y522M 

C307 8 

GT25 

CTY010/RT675 75C UL 

 

28P 

PLT2S-M 

 

MT9X3 

FCAMPAD 90X38 771/4773  

 

.5 

49B 

771/4773 

 

ZX4D11651 

FILTER CHOKE AP60/50         5 

B  

01B 

ZX4D11651 

TX301 2 

GCNX2 

P CLIP 6.4MM I/D 

 

04H 

NX2 

 

KP3M6 

SCREW M3 X 6 PAN HD POZI 

 

05T 

KP3M6 

 

KP4M10 

SCREW M4 X 10 PAN HD POZI  

 

05T 

KP4M10 

 

NF3M 

FULL NUT M3 

 

05T 

NF3M 

 

TS542 

SOLDER TAG  

 

02U 

HGBV623/1000ET 

 

WS3M 

SPRING WASHER M3 

 

05T 

WS3M 

 

WS4M 

SPRING WASHER M4 

 

05T 

WS4M 

 

WW3M 

WAVEY WASHER M3 

 

24L 

LS508/54 

 

4N6050PC 

POWER CONVERSION ASSEMBLY 

 

 

4N6050CD 

CENTRE DIVIDER ASSEMBLY 

 

 

GRM79H 

GROMMET 11/2X1 M79H 

 

60M 

M/79/H 

 

KP3M10 

SCREW M3 X 10 PAN HD POZI  

 

05T 

KP3M10 

 

KP3M8 

SCREW M3 X  8 PAN HD POZI 

 

05T 

KP3M8 

 

NF3M 

FULL NUT M3 

 

05T 

NF3M 

 

NV320D 

POP RIVET 2.4MM DIA DOMED HD 

 

08T 

TAPD+33+BS 

 

WF3M 

FLAT WASHER M3 

 

05T 

WF3M 

 

WS3M 

SPRING WASHER M3 

 

05T 

WS3M 

 

4N6050H 

HEATSINK ASSEMBLY 

A  

 

 

4N6050DH 

DIODE HEATSINK ASSEMBLY 

 

 

7SU3945 

DIODE CROSS LINK             A 

00F 

4SUCJ3945 

THT401 

7SX2182 

DIODE HEATSINK  

C  

00F 

2SUBA2182 

 

CR44N70SM 

4n70F 20% 400V           A     

 

03A 

L1A-4N704A 

C403 

DG54V200 

200V 2X50A 60NS ITOP 

 

29S 

BYV54V-200 

D401 

KP4M10 

SCREW M4 X 10 PAN HD POZI  

 

05T 

KP4M10 

 

KP4M16 

SCREW M4 X 16 PAN HD POZI 

 

05T 

KP4M16 

 

RW233R0JJ 

33R0     5%  2W50 

 

04E 

74ER 

R403 

TM60032 

STANDOFF TERMINAL M2.5 

 

01H 

W6003/M2.5+(W2130) 

 

TS0B238 

SOLDER TAG OBA/M6 

 

05R 

201020 

 

TS3B363 

SOLDER TAG 3BA 

 

05R 

201017 

 

WF4M 

FLAT WASHER M4 

 

05T 

WF4M 

 

WS4M 

SPRING WASHER M4 

 

05T 

WS4M 

 

4N6050FH 

FET HEATSINK ASSY 

 

 

5N6050FH 

FET CIRCUIT BOARD  

 

 

BC1372 

FET C.B. 

01K 

S1SAB13720 

B                    

CL42N20WM1 

2n20F 20% 1K0V   

  

47L 

106-362 

C4 

CRA1U00SM 

1U00F 20% 400V           A     

  

03A 

E1A10204A 

C1-3 

DAOMIT 

DIODES OMITTED 

 

00F 

DAOMIT 

D1 2                 

MC2 

CERAMIC BEAD LARGE  

 

57M 

IPB2 

R1 2 FIT X1 PER LEG       

RM233R0FF 

33R0     1%  0W60 50PPM  250V 

 

18P 

MRS25 

R3-8                 

RW3200RNJ 

200R     5%  9W00 

 

04E 

16ER 

R1 2 (FIT X1 MC2 PER LEG) 

TP15080 

CIRCUIT BOARD PIN 8mm 

 

02B 

B1.5X0.20X8MST 

X8 (X1-8 COMP SIDE) 

VAOMIT 

TRANSISTOR / IC OMITTED 

 

00F 

IN+HOUSE+REFERENCE  Q1-6                 

7SU4094 

TRANSISTOR SUPPORT 

00F 

4SUDA4094 

 

7SX3922 

HEATSINK 

00F 

3SUBA3922 

        

DG12PI600 

600V 12A 50NS DO220I 

 

29S 

STTA1206DI 

D1 2 (JIG 223) ENSURE COMP IS BYT12PI600 

MF3888 

CRAYOTHERM INSULATOR 

72C 

4SUOO3888 

        

SR090L06 

T/TRIP STUD 90C N/C 300MM LDS 

 

34T 

L0609005300 

THT1 2  

VFP450IR 

500V 13A 400MR  TO3P    STATIC 

 

10I 

IRFP450 

Q1-6 (JIG 182) 

7NU0993523 

HEAT SINK SUPPORT  

00F 

3BA0993523 

 

7NU0993524 

HEAT SINK COVER              A 

B  

00F 

2BA0993524 

 

4N6050M 

MAIN ASSEMBLY 

C  

 

 

7NF0993530 

INVERTER SPACER 

A  

00F 

4OO0993530 

 

7NF0993537 

INSULATOR PLATE 

A  

00F 

4OO0993537 

 

7NR2626524 

RES BAR 

B  

00F 

4OO2626524 

 

7NU0993512 

CAP BUS BAR B 

A  

00F 

3CJ0993512 

 

7NU0993513 

POSITIVE BUS BAR 

D  

00F 

2CJ0993513 

 

7NU0993514 

NEGATIVE BUS BAR 

D  

00F 

2CJ0993514 

 

7NU0993515 

CONNECTOR CLAMP 

00F 

4CJ0993515 

 

7NU0993516 

RESISTOR  CLAMP 

00F 

4CJ0993516 

 

7NU0993536 

MAIN COVER PLATE 

B  

00F 

3BA0993536 

 

BC239 

POWER CONVERSION BOARD  

B  

01K 

1BS23B2390 

HAND SOLDER ONLY 

CB547N0SM 

47n0F 20% 400V MKC  5X18 R15.0 

 

159W 

MKC10 

C408 9 

CED2M30LM 

  2300UF 20%  75V       R 12.5 

 

92B 

ALS20B-1021DF 

C404-407(M13622) 

CRA3U30LJ 

3U30F 5%0 100V MKT 12X27 A32.0 

 

70S 

MKT1813-533/0 

C411 2 

CX547N0PM 

47NF    20%  250V        R150 

 

13R 

PME+271M547M 

C413 4 

DTGN71 

STUD DIODE 

 

03W 

SW02PCN075 

D402 

MC1 

CERAMIC BEAD SMALL 

 

57M 

IPB/1 

R405 X1/L 

RAOMIT 

RESISTORS OMITTED 

 

00F 

RAOMIT 

R409 

RW0R030RKT 

0R03    10%  50W0 

 

94M 

HSA50-R1077 

R406-408 

RW0R100JJ 

0R10     5%  2W50 

 

04E 

W21/74ER 

R405 (MC1 X1/L) 

RW3680RMK 

680R    10%  7W00 

 

17V 

210-9 

R404 

TBM2510PS 

STRAIGHT PIN HEADER 10 WAY 

 

23M 

6410+22-27-2101 

SK20 

TP1510 

CIRCUIT BOARD PIN 10mm 

 

26P 

B1.5X0.25X10MS 

X4 

VT3442 

2N3442 140V 10A TO3  N 

 

70H 

2N3442 

TR401 

ZT4D20470 

CHOKE AP60/50 

01B 

ZT4D20470 

TX406 

ZV8A20400 

CHOKE OUTPUT AP60/50 

B  

01B 

ZV8A20400 

TX405 

ZZ6F20460 

INVERTER AP60/50 

01B 

ZZ6K20460 

TX404 

5N6050D 

DRIVE CB ASSY            

 

 

BC240 

DRIVE TRANSFORMER BOARD 

01K 

2BS12B2400 

CLA1U00SJ 

1U00F 5%0 400V MKP 13X31 R27.5 

 

18P 

378-52105 

C410 

DZ218V0H 

18V       5%  1W30 

 

01P 

BZV85-C18V 

Z1A 2A;1B 2B 

Содержание AP10030

Страница 1: ...AP3080 AP6050 AP10030 AP3080 AP6050 AP10030 AP3080 AP6050 AP10030 AP3080 AP6050 AP10030 User Service Manual User Service Manual User Service Manual User Service Manual Part N 9HAP1kW Wayne Kerr Elect...

Страница 2: ...ce is implied for the use of any patented feature It must not be reproduced in whole or in part or used for tendering or manufacturing purposes except under an agreement or with the consent in writing...

Страница 3: ...13 5 4 RACK MOUNTING 13 6 OPERATING INSTRUCTIONS 15 6 1 FIRST TIME OPERATION 15 6 2 CONNECTING THE LOAD 16 6 3 PROTECTIVE CIRCUITS 17 6 4 OPERATING MODES 20 6 5 LINE IMPEDANCE TEST 30 6 6 CURRENT MONI...

Страница 4: ...d NEUTRAL terminal to BLUE lead EARTH terminal to GREEN YELLOW lead The user must also ensure that the protective earth lead would be the last to break should the cable be subject to excessive strain...

Страница 5: ...sitive parts must wear a wrist strap which provides a leaky path to ground impedance not greater than 1 megaohm 4 Components or circuit board assemblies must be stored in or on conductive foam or mat...

Страница 6: ...B2529 1 Note In the event of damage in transit or shortage in delivery separate notices in writing should be given to both the carriers and Wayne Kerr Electronics Limited within three days of receipt...

Страница 7: ...voltage availability Overvoltage Limit To protect the load from the inadvertent application of an excessive voltage the power supply incorporates an Overvoltage Limit OVL this causes the supply to dow...

Страница 8: ...ilable for voltage and current ranges 10 20 30 20 40 60 80 34A 40A 50A 66 7A 80A 20 40 60 50 30 10 10 20 30 40 50 16 7A 20A 25A 33 5A 40A 50A 100 80 60 40 20 10A 12 5A 16 7A 20A 25A 30A 10 20 30 34 Fi...

Страница 9: ...100 90 of maximum current Programming Response Time Maximum time for output voltage to change from 2 volts to maximum or from maximum to 2V and settle within 200mV band UP Full load 3 4 120ms No load...

Страница 10: ...ption is fitted BUS indicates the unit is under bus control LSN indicates receiving data from the bus TLK indicates transmitting data on the bus and SRQ indicates that a service request has been initi...

Страница 11: ...rear of unit in rack Panel Symbols Used Refer to handbook Alternating current Earth ground terminal CAUTION Risk of electric shock On Off ORDER CODES AP30 80 11AP3080 As above with IEEE488 2 interfac...

Страница 12: ...minutes to allow capacitors to discharge 2 Remove the three fixing screws from each side trim 3 Remove side trims 4 Working from the front and for each cover slide backwards to clear recess in front...

Страница 13: ...circuit breakers The power supplies are intended for use with mains wiring capable of supplying the rated input current without undue voltage drop See specification for maximum input currents The prot...

Страница 14: ...ger Note orientation of insert with styling cut out opposite cut out in handle Insert screwdriver into other end and repeat procedure This will relieve the small tapered pins of the insert from the th...

Страница 15: ...fitted with the IEEE488 option ensure that the Bus connector is disconnected and the Bus Local switch is in the Local position Both items are located on the back panel Fig 6 1 Front panel controls and...

Страница 16: ...fully anticlockwise position and rotate the current control fully anticlockwise Depress the output enable switch and confirm that the CI legend is illuminated thus indicating that the power supply is...

Страница 17: ...us area being lit The green output enable LED will be illuminated The over range condition occurs when the output power demanded from the supply exceeds 1000W The output does not shut down but will be...

Страница 18: ...ictions or a too high ambient temperature Refer to instructions for filter cleaning see section 9 1 Resetting Overtemperature Trip When the unit has cooled sufficiently the overtemperature trip can be...

Страница 19: ...lts and current flowing IN Output V I Normal CI operation meters read O P volts and current flowing IN Output V I Overrange condition IN Zero Overtemperature trip shutdown IN Zero Overvoltage trip out...

Страница 20: ...int has been set higher than the actual current flowing into the load then the CV legend will be illuminated Whenever the load current reaches the previously set current limit figure the power supply...

Страница 21: ...occur to the unit The supply can work continuously in this mode without damage but it will not meet specifications In particular the output ripple increases substantially and the output has poor regu...

Страница 22: ...ing barrier strip terminals 10 and 11 and 12 and 13 c Connect the sense leads from the sense terminals to the load as shown in the diagram Fig 6 3 d Connect the load and replace the terminal cover e C...

Страница 23: ...6 7 7 8 8 9 10 Vprog Common S S Programming resistor 0 4k7 for 0 to full scale O P Optional resistor for lower voltage limit Optional resistor for upper voltage limit 6 Voltage programme input 7 Front...

Страница 24: ...rably low source impedance Fig 6 6 Connections for voltage programming output voltage Connecting up a variable voltage source as shown will programme the output voltage of the power supply from zero t...

Страница 25: ...event this an upper limit programming resistor should be connected close to the barrier strip terminals The overvoltage limit may also be used to give protection against such occurrences 6 4 4 Auto Pa...

Страница 26: ...olled by the master The current controls of the slaves are inoperative The voltage limits of the slaves should be set above the highest output voltage that is required This ensures that all the slaves...

Страница 27: ...atively the current readings of the master and all the slaves can be summed necessary if different models are placed in parallel This should be taken into account when programming current limit settin...

Страница 28: ...5 6 6 6 7 7 7 8 8 8 9 9 9 10 10 10 11 11 11 12 12 12 13 13 13 Master Load S S S S S S S S S Slave1 Slave 2 y x y x Fig 6 9 Connections for master slave series operation c Calculation Of Resistor Divid...

Страница 29: ...g when the total load voltage is at the desired limit point When the master trips the slave units will programme down to minimum output voltage The trips on the slave units can also be set if required...

Страница 30: ...vering full output power High a c line impedance can be due to poor mains wiring long extension leads or poor connections somewhere in the system Measuring the a c line voltage is an insufficient test...

Страница 31: ...The voltmeter should be connected between terminals Imon and S The output impedance at terminal Imon is 5k 6 7 Inhibit Terminal The INHIB terminal output inhibit is an extra facility which can be use...

Страница 32: ...through an R F I filter to the auxiliary transformer fan and mains rectifier diodes The soft start relay RL301 schematic and power conversion diagrams short circuits the soft start resistor R301 sche...

Страница 33: ...onstant voltage mode operation the output voltage is divided by R184 P10 R183 and R182 and fed to either the overvoltage trip comparator IC22 control board diagram or the control amplifier IC13 pin 2...

Страница 34: ...15 pin 6 is high and IC1 A output is low TR4 will be off The opposite is true of IC1 B controlled by the voltage amplifier Therefore TR5 will be on and constant voltage indicated In the unregulated mo...

Страница 35: ...ent when the enable switch is on or the output voltage and current settings when the enable switch is off The voltmeter circuit consists of IC1 and display driver IC2 front panel circuit diagram The a...

Страница 36: ...err see section 9 3 or to any approved service depot operated by our agents overseas Fig 8 1 Control Board Pot Positions Fig 8 2 Display board pot positions 8 1 Equipment Needed For Recalibration 25A...

Страница 37: ...front panel meter corresponds with the calibrating DVM on AP100 30 a reading of EEE indicates 100V Adjust P1 on the meter board if necessary e Reduce resistance box to 470 and adjust P6 to obtain 0 5...

Страница 38: ...ith output enable off adjust the front panel voltage control to obtain 97 5V for AP100 30 58 5V for AP60 50 and 29 25 for AP30 80 on the front panel meter Adjust P5 on the front panel board until the...

Страница 39: ...oad to obtain 30A 0 05A for AP100 30 50A 0 05A for AP60 50 and AP30 80 d Adjust P4 I sense balance on control board until front panel meter reads 30 0A 0 1A for AP100 30 50 0A 0 1A for AP60 50 and AP3...

Страница 40: ...osed on the low frequency ripple waveform The peak peak ripple figure is measured as the voltage between the peaks of the brightest part of the waveform Higher frequency noise may not be visible 10mSe...

Страница 41: ...nal whilst the unit is delivering the desired output and checking for any reading on the oscilloscope Noise generated by the power supply will tend to be short spikes or bursts of high frequency noise...

Страница 42: ...cloth Should it be required weak detergents can be used No water should enter the power supply If the insides of the unit become clogged with dust a service will be required do not attempt to wash do...

Страница 43: ...ceptional circumstances and at the discretion of the Service Manager a charge for labour and carriage costs incurred may be made Our responsibility is in all cases limited to the cost of making good t...

Страница 44: ...decade blocks delimited by colons second and subsequent numbers within a decade block represent only the unit value of the location the tens and hundreds values being implied e g for a component locat...

Страница 45: ...ATSINK B 2 00F 3SUBA3922 DG12PI600 600V 12A 50NS DO220I 2 29S STTA1206DI D1 2 JIG 223 ENSURE COMP IS BYT12PI600 MF3888 CRAYOTHERM INSULATOR B 6 72C 4SUOO3888 SR090L06 T TRIP STUD 90C N C 300MM LDS 2 3...

Страница 46: ...REW M3 X 8 PAN HD POZI 2 05T KP3M8 KP4M10 SCREW M4 X 10 PAN HD POZI 2 05T KP4M10 KP4M20 SCREW M4 X 20 PAN HD POZI 1 05T KP4M20 RF16R02NJ 6R0 6R0 DUAL 5 11W0 1 17V 226 216 R301 SR20016 HI V POWER 12VDC...

Страница 47: ...1K80FF 1K80 1 0W60 50PPM 250V 5 18P MRS25 R45 152 3 77 8 RM42K20FF 2K20 1 0W60 50PPM 250V 4 18P MRS25 R63 96 129 220 RM42K70FF 2K70 1 0W60 50PPM 250V 3 18P MRS25 R111 32 56 RM43K30FF 3K30 1 0W60 50PPM...

Страница 48: ...N C63 95 CR44N70LJ 4n70F 5 0 100V KT 3X08 R05 0 1 159W FKS2MIN C62 CR533N0KM 33n0F 20 63V MKT 3X08 R05 0 1 159W MKS2 C53 CR6100NKM 100nF 20 63V MKT 3X08 R05 0 1 159W MKS2MIN C65 CR6100NLM 100nF 20 100...

Страница 49: ...F 33K0 1 0W60 50PPM 250V 2 18P MRS25 R14 9 SA16700 SWITCH CAP GREY 2 24M 16 700 SB15500 PUSH BUTTON SWITCH BLK PB 1 24M 15 501 BLK PB SW1 SB15550 PUSH B SW 15 550 LATCH RED PB 1 24M 15 551 03 SW2 TIH2...

Страница 50: ...ST253A90 CCT BREAKER 25 33A 250V 2POLE 1 21C BA2 B0 24 625 212 D CB401 TL72332 JUMPER LINK 6 26V 7204 3502 A120 WF3M FLAT WASHER M3 2 05T WF3M WN8B FLAT WASHER 8BA M2 5 NYLON 66 2 40P 011 0763 WS3M SP...

Страница 51: ...B CL42N20WM1 2n20F 20 1K0V 1 47L 106 362 C4 CRA1U00SM 1U00F 20 400V A 3 03A E1A10204A C1 3 DAOMIT DIODES OMITTED 2 00F DAOMIT D1 2 MC2 CERAMIC BEAD LARGE 4 57M IPB2 R1 2 FIT X1 PER LEG RM233R0FF 33R0...

Страница 52: ...52 CR510N0LJ 10n0F 5 0 100V KT 3X08 R05 0 24 159W FKS2 C13 7 8 22 38 40 3 5 8 51 6 8 70 2 6 9 80 8 90 2 CR510N0LM 10n0F 20 100V KT 3X08 R05 0 2 159W FKS2MIN C41 96 CR6100NLM 100nF 20 100V MKT 3X10 R07...

Страница 53: ...CN BCMOS 4X 2 I P NAND 14 DP STAT 2 23N CD4093BCN IC4 28 VF540 IRF540 STATIC 1 10I IRF540 TR33 VF9522 FET IRF9522 STATIC 1 10I IRF9520 TR31 VP10218 TRANSISTOR PAD 10218 2 27K EPX003 Z3 4 VS14L IC SKT...

Страница 54: ...SSEMBLY A 1 4 5N6050F1 FRONT PANEL DISPLAY C B G 1 5NAPDISA DISPLAY CB AXIAL ASSY A 1 BC235 FRONT PANEL DISPLAY BOARD C 1 01K CBP32B2350 BOARD TO BE ATE TESTED RM15R10FF 5R10 1 0W60 50PPM 250V 2 18P M...

Страница 55: ...015 YP3079BLK 14AWG BLACK UL1015 51 09A 14AWG UL1015 YP3079BN 14AWG BROWN UL1015 44 09A 14AWG UL1015 YP3079RD 14AWG RED UL1015 45 09A 14AWG UL1015 YP702GYV 7 0 2 GREY 105 84 08I 30 X 0 1 SOFLEX TQ YP7...

Страница 56: ...0C N C 300MM LDS 2 34T L0609005300 THT1 2 VFP450IR 500V 13A 400MR TO3P STATIC 6 10I IRFP450 Q1 6 JIG 182 7NU0993523 HEAT SINK SUPPORT C 1 00F 3BA0993523 7NU0993524 HEAT SINK COVER A B 1 00F 2BA0993524...

Страница 57: ...05T WS4M YT18 T C WIRE 18SWG 062 55M 18SWG 5N6050IP I P FILTER CB A 1 5 BC238 FILTER 60 50 S C 1 01K 2BS23B2380 B CAOMIT CAPACITORS OMITTED 2 00F CAOMIT C312 3 CX6470NPM 470NF 20 250V R250 5 13R PME...

Страница 58: ...PPM 250V 4 18P MRS25 R57 60 133 207 RM46K80FF 6K80 1 0W60 50PPM 250V 3 18P MRS25 R2 86 131 RM48K20FF 8K20 1 0W60 50PPM 250V 4 18P MRS25 R151 4 76 9 RM49K10FF 9K10 1 0W60 50PPM 250V 2 18P MRS25 R28 9 R...

Страница 59: ...KT 3X10 R07 5 1 85S B32511 D3223K 10PCM C65 DAOMIT DIODES OMITTED 1 00F DAOMIT D33 DLINK22 22SWG TC LINK F 1 00F DLINK22 D23 YT22 T C WIRE 22SWG 035 55M 22SWG PM3500RKV 500R 10 PRESET VERT STURN 1 02S...

Страница 60: ...SW 15 550 LATCH RED PB 1 24M 15 551 03 SW2 TIH2526NT1L 26 WAY PIN HEADER 1 25V M52 1226 660 SK1 TK30513 PIN LINE SOCKET 3WAY 9 35R 3 0513 10 LED4 7 14 TP7401 12WAY STAKED MALE CONTACT 4 07A 1 163740...

Страница 61: ...CAP C150 SIF BLK 2 01S C150 HK15025 KNOB S150250 SIF BLK 2 01S S150250 HL9X30 BLANK 9X30 P120 1 51D P120 HMDEC10 FILTER FOAM DECLON 17mm THICK 01 14D 10PPI 17MM THICK 125 X 115MM HR3 GUIDE RAIL RCG3...

Страница 62: ...Page 62 11 CIRCUIT DIAGRAMS 3ZV0993211 Connection 2ZX0993201 Power Conversion Section 1SZX0320 Sheet 1 Control Board 3SZX0320 Sheet 2 Control Board Component Variation Table 2ZW0993210 AP 1kW Schemati...

Страница 63: ...AP 1kW Power Supplies Issue 2 Circuit Diagrams Page 63...

Страница 64: ...AP 1kW Power Supplies Issue 2 Circuit Diagrams Page 64...

Страница 65: ...AP 1kW Power Supplies Issue 2 Circuit Diagrams Page 65...

Страница 66: ......

Страница 67: ......

Страница 68: ......

Страница 69: ......

Страница 70: ......

Отзывы: