Wayne Kerr AP 1kW Power Supplies • Issue 2
19
Front Panel Shows
Condition
CV
LED
CI
LED
Enable
LED
UNREG
LED
OT
LED
OVL
LED
ENABLE
BUTTON
METER
OUT
Set volts &
Amps
Voltmeter & ammeter
reading preview volts &
amps set by the front
panel
IN
Output V & I
Normal CV operation
meters read O/P volts and
current flowing.
IN
Output V & I
Normal CI operation
meters read O/P volts and
current flowing.
IN
Output V & I
Overrange condition.
IN
Zero
Overtemperature trip
shutdown.
IN
Zero
Overvoltage trip output
shutdown
Lit for
short
periods
IN
Output V & I
Occurs for short periods
when reducing O/P volts
with low load and indicates
dynamic bleed circuit is in
operation.
IN
Zero
Low mains or mains
dropout.
IN
Zero
Terminal cover removed
or “INHIB” in operation.
- Normal operation
Comment [PMA1]: