39
5. System Configuration Menu
This menu contains all editable parameters on the door system. A passcode is required in order to change the settings. The door will not operate
when inside the menu.
A. Timers
1. Contains all the same timers in the Express Menu.
2. Setting the timer to 0 disables the timer.
B. Outputs - Configurable relay activation based on custom door status/events. Table on page 40 lists all available status/events.
C. Inputs - Inputs with configurable actuator functions. Table on page 39 lists all functions available with each input.
D. Position sensor -Do not update/menu is not used
E. Reference -Do not update/menu is not used.
F. Safety Edges -1 or 2 safety edge select as well as safety edge Type.
G. Photoeyes -Do not update/menu is not used
H. Motor Configuration - Do not update / Engineering use only.
I. Frequencies - Do not update / Tech Services use only.
J. Ramps - Do not update / Tech Services use only.
K. DG-XNET -Do not update / Menu not used.
L. Options -Do not update / Menu not used.
M. System -Do not update / Engineering use only.
6. Configuration -Inputs/Outputs
A. Inputs. There are 3 parameters that can be set. Refer to
FIG 6-C
(close up view of Input relays)
1. Function -A list of functions can be selected to determine how the input should operate the door.
2. Name -a name can be applied to the specific function
3. Logic -The logic for activation of the door can be chosen. Either Normally Open (0VDC ->24VDC) or Normally Closed (24VDC ->0VDC).
B. Outputs. Refer to
FIG 6-D
(close up view of Output relays)
1 Function -list of functions can be selected to activate the output relay
2. The output is dependent on the input wired into the relay pins 2, 5, 7, 9.
3. Output relays 1 & 2 consist of two relay outputs, a NO and NC. Output Relays 3 &4 contain only NO relay activation.
MENUS
(continued)