4-29
Forward Telemetry Frequency
Use the
UP
and
DOWN
arrow keys or the numeric keypad to enter
the telemetry frequency.
NOTE: For successful Stealth mode operation, the Rx Forward
Telemetry frequency (3HRV) must match the Tx telemetry
frequency setting of the Model 3SRV.
Caution: Do not place the telemetry signal too close to the diplex
filter cut-off frequency in that roll-off may attenuate the
telemetry signal to the degree that communication fails.
This same caution applies to placing the signal in the high
end roll-off region.
Forward Telemetry Level
This is the level of the carrier that the 3HRV uses to transmit
telemetry data. Use the edit box to set the Telemetry Level to an
appropriate value. When adjusting the Telemetry Level, take into
consideration the following losses; system, summing network, test
point, and amplifier desired input.
Use the
UP
and
DOWN
arrow keys or the numeric keypad to enter
the telemetry level (20-50 dBmV).
Reverse Telemetry Frequency
This is the frequency at which 3SRV units with the Reverse Sweep
option will transmit telemetry data. Optimally this will be in a
portion of the reverse frequency band with at least 1 MHz free, and
at best case, in the high end of the return band to avoid potential
interference from ingress.