76
•
Advanced Topics
WAVECOM Decoders v6.15 W40PC, W41PC, W51PC
dimensional Real-Time-FFT display only shows a fraction of the data, depending on the
modulation method. In contrast the FFT waterfall display gives a display also in the time
domain
Waterfall analysis is started by clicking on a desired bandwidth "
BW 500 Hz
", "
BW 1000
Hz
", "
BW 4000 Hz
" or "
BW 24 kHz
".
The W51PC also supports "
BW 2 kHz
", "
BW 48 kHz
", "
BW 96kHz
".
A time histogram is displayed on the right-hand side of the display.
The options "
Average Factor"
and "
Window Type
" are identical to the same Real-time
FFT functions.
From the "
Options/Period
" menu the time unit per measurement may be selected. The
lowest value is 50 ms corresponding to a sampling rate of 20 pictures/s. For the highest value
of 10'000 ms a measurement is done once every 10 seconds, giving a total time span of more
than 400 seconds.
By clicking on the graph the display will be
paused
and
measurement cursors
appears.
Several
color schemes
are available through the right-click menu.
HF REAL-TIME WATERFALL
The Analysis is started with the input, gain, translation frequency etc. that was used, last time in a HF mode. This
selection is only available in the menu Preferences… the "When selecting the toolbar
"Analysis Buttons" start HF analysis mode" is not enabled. (See Preferences…
on page 54)
Содержание W40PC
Страница 1: ...WAVECOM Decoders v6 15 W40PC W41PC W51PC by WAVECOM Elektronik AG...
Страница 56: ...48 General Operating Procedure WAVECOM Decoders v6 15 W40PC W41PC W51PC...
Страница 238: ......
Страница 242: ......
Страница 246: ......
Страница 252: ...244 Manual History WAVECOM Decoders v6 15 W40PC W41PC W51PC W40PC New modes AMSAT P3D AUM 13 CIS 36 50 CIS50 50 MFSK 20...