Page 9
Note: On 3/8” drain saddles, the black 3/8” drain tube must be as
SHORT and STRAIGHT as possible. Make sure there is a
downward slope with no low spots between this line and the
drain. Leaving this line too long or with low spots can lead to
water building up and leaking out of the air gap of the faucet.
Locate the 3/8” drain tube attached to the RO faucet. Measure
the tube from the faucet to the drain saddle on the drain pipe and
make a straight cut to the correct length. Push the open end of the
3/8” black tube into the 3/8” drain saddle. Make sure it is pushed
in all the way to the tube stop.
( B ) 3/8” Tube Fitting Drain Saddle
Locate the red 1/4” drain tube attached to the RO faucet.
Connect the open end of tube to the quick connect fitting on
the top of the RO Module labeled “Drain” making sure the tube
is pushed in all the way to the tube stop.
Step 13B-1
Step 13B-2
Locate the blue 3/8” tube attached to the RO Faucet. Connect
the open end of the blue 3/8” tube to the quick connect fitting
on the right side of the RO Module labeled “FAUCET” making
sure the tube is pushed in all the way to the tube stop. Continue
to step 15 on the next page.
Step 14
Faucet Tube Connection