8  Installation and commissioning

DANGER

Electrical energy!

Risk of death from electric shock.

•  Work on parts carrying live voltage must be carried out 

by qualified electricians only.

•  Disconnect the power supply of the system and secure 

it to prevent it from being switched on again before car-
rying out any installation, maintenance, cleaning or repair 
work.

NOTICE

The installation and commissioning of

the Isomix-F must be carried out only by trained per-
sonnel who have been authorized by the manufacturer. 

!

 

CAUTION

When repairing the unit or replacing

parts, be sure to observe the specified installa-
tion positions and flow directions of the parts being 
replaced!

!

 

CAUTION

Material damage!

Pressure shocks may occur if the stop valve is opened 
or closed quickly.

•  Always open and close the stop valves slowly and in a 

controlled way.

8.1  Installation

All screw fittings must be checked and tightened if 
necessary prior to installation and commissioning!  
For the torques of the fitting see „5 Technical data“ 
page 4�

!

 

WARNING

Hot water!

Risk of severe scalding.
Do not reach into the hot water when emptying the 

Isomix-F. Ensure that the Isomix-F has cooled down 

before carrying out maintenance, cleaning and repair 

work.

During installation it must be ensured that:
•  the cables from the pump and temperature limiter 

are not damaged or kinked 

•  the sensor capillary tube is not damaged or kinked
•  The cables must not be under tension�

1.  Fit the control station to the manifold with the 1" nuts and 

associated seals. 

The control station can be fitted on the right or left of 
the manifold by turning the eccentric screw fitting (5, 
Fig� 8-1), also upside down�

2.  Fit the temperature limiter to the supply collector pipe on 

the manifold.

3.  Connect the control station to the power supply.

Further information about electrical connection of the 
control station can be found in the separate documen-
tation for the assemblies�

4.  Set the temperature on the (optional) temperature limiter 

to approx. 55 °C.

NOTICE

To ensure that the pump runs only when

heat is required, the manufacturer recommends con-
necting the pump to a pump relay (e.g. the pump logic 
of an electrical control distributor that also controls 
the actuators). Alternatively, the pump can be operat-
ed with a timer switch. 

8.2  Mounting in combination with Heat  

Interface Unit HIU 2

For use in combination with the Watts HIU 2 Heat Interface 
Unit, the Isomix-F must be converted (overhead) and the 
eccentric rotated.

1.  Release nut (A, Fig. 8-1)
2.  Rotate eccentric (5, Fig. 8-2)
3.  Position the temperature limiter (8,  Fig. 8-2)

A

5

Fig. 8-1 

8

5

Fig. 8-2 

Содержание Isomix-F

Страница 1: ...Isomix F Control station for constant maintenance of the flow temperature in surface heating systems Installation and Operating Manual translated from the original operating manual WattsWater eu ...

Страница 2: ...cording to Machinery Directive 2006 42 EC has been issued for the Isomix F product 1 3 Product features All connections to the system have 1 male thread and flat sealing Very convenient controls compact space saving design Contents 1 General information 2 1 1 Important information about this manual 2 1 2 Product conformity 2 1 3 Product features 2 2 Safety 3 2 1 Presentation of safety information ...

Страница 3: ... operated by people including children with limited physical sensory or mental capacities or by people with insufficient experience or previ ous knowledge 2 4 Foreseeable misuse The following is considered to be foreseeable misuse Operating the Isomix F beyond its specifications Improper use of the Isomix F Modifications to the Isomix F that have not been agreed with the manufacturer Use of replac...

Страница 4: ... circuit and thus keeps the flow tem perature constant within a narrow range The actual value can be checked on the thermometer 5 Check valve 6 pre vents a short circuit of the primary circuit The temperature limiter 8 switches off the circulating pump 1 when the supply temperature is exceeded thus prevent ing the panel heating system from overheating 5 Technical data Hydraulic performance data Ma...

Страница 5: ...no 10070292 5 EN ENGLISH 6 Overall dimensions G1 G1 22 5 82 ca 225 ca 98 210 65 5 25 1 Fl 1 Fl Fig 6 1 Overall dimension 7 Pressure loss diagram 1 10 100 1 000 100 1 000 10 000 Fig 7 1 Pressure loss diagram Flow rate l h Pressure loss mbar ...

Страница 6: ...own before carrying out maintenance cleaning and repair work During installation it must be ensured that the cables from the pump and temperature limiter are not damaged or kinked the sensor capillary tube is not damaged or kinked The cables must not be under tension 1 Fit the control station to the manifold with the 1 nuts and associated seals The control station can be fitted on the right or lef...

Страница 7: ...tion of flow until the air and any contamination has been removed from the circuit completely The non return valve 14 in the mixer bypass prevents any short circuit when flushing 10 Repeat the process for all the heating circuits Fig 8 3 Fig 8 4 NOTICE Flushing is permitted only in the direction of flow of the heating circuits i e the water must enter through the flow manifold and come out of the ...

Страница 8: ...open Hot water is injected from the primary heating circuit As a result the control station heats up When the maxi mum temperature of the TL is reached the contact opens The pump does not switch on again Remove TL from the control station and fit to supply heat ing circuit manifold See 1 1 2 Underfloor heating flow temperature cannot be set to the required value or the feed temperature fluctuates ...

Страница 9: ...e seals as required 2 Functional check Check that settings and operating and performance parameters are set correctly Check flow noise during operation Ask users if there are any noticeable problems 3 Action to be taken following maintenance work Check that all screw fittings that were unscrewed have been retightened and retighten if necessary Remove all tools materials and other equipment used fr...

Страница 10: ...omix F properly or commission a spe cialist company to do so 3 Sort the assemblies and component parts into recyclable materials hazardous substances and operating materials 4 Dispose of the assemblies and components in accord ance with local laws and regulations or take them to be recycled 11 1Return to the manufacturer Get in contact with the manufacturer if you would like to return the Isomix F...

Отзывы: