Page 11
Substance
Percent
Reduction
Influent Challenge
Concentration
(mg/L unless noted)
Maximum Permissible
Product Water
Concentration
ALACHLOR*
>98%
0.05
0.001
ATRAZINE*
>97%
0.1
0.003
BENZENE*
>99%
0.081
0.001
BROMODICHLOROMETHANE (TTHM)*
>99.8%
0.300 +/- 0.30
0.015
BROMOFORM (TTHM)*
>99.8%
0.300 +/- 0.30
0.015
CARBOFURAN (Furadan)*
>99%
0.19
0.001
CARBON TETRACHLORIDE*
98%
0.078
0.0018
CHLOROBENZENE (Monochlorobenzene)*
>99%
0.077
0.001
CHLOROFORM (TTHM)*
>99.8%
0.300 +/- 0.30
0.015
CRYPTOSPORIDIUM (see Cyst)
99.99%
minimum 50,000/mL
99.95%
CYST
99.99%
minimum 50,000/mL
99.95%
2, 4-D*
98%
0.110
0.0017
DBCP (see Dibromochloropropane)*
>99%
0.052
0.00002
1,2-DCA (see 1,2-DICHLOROETHANE)*
95%
0.088
0.0048
1,1-DCE (see 1,1-DICHLOROETHYLENE)*
>99%
0.083
0.001
DIBROMOCHLOROMETHANE
(TTHM;Chlorodibromomethane)*
>99.8%
0.300 +/- 0.30
0.015
DIBROMOCHLOROPROPANE (DBCP)*
>99%
0.052
0.00002
o-DICHLOROBENZENE (1,2 Dichlorobenzene)*
>99%
0.08
0.001
p-DICHLOROBENZENE (para-Dichlorobenzene)*
>98%
0.04
0.001
1,2-DICHLOROETHANE (1,2-DCA)*
95%
0.088
0.0048
1,1-DICHLOROETHYLENE (1,1-DCE)*
>99%
0.083
0.001
CIS-1,2-DICHLOROETHYLENE*
>99%
0.17
0.0005
TRANS-1,2- DICHLOROETHYLENE*
>99%
0.086
0.001
1,2-DICHLOROPROPANE (Propylene Dichloride)*
>99%
0.08
0.001
CIS-1,3- DICHLOROPROPYLENE*
>99%
0.079
0.001
Performance Data Sheet
Watts Premier
8716 W Ludlow Drive Suite #1
Peoria, AZ 8538
Model: Filter Pure UF3
GENERAL USE CONDITIONS:
1. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
2: Operating Temperature:
Maximum 100° F (40.5°
C)
Minimum 40°
F (4.4°
C)
3: Operating Water Pressure:
Maximum 85 psi (5.98 kg/cm
2
)
Minimum 20 psi
4: Maximum flow Rate:
0.50 gpm (1.89 lpm)
5: Rated Capacity:
150 Gallons (570 liters)
This system has been tested according to NSF/ANSI Standard 42 and 53 for the reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or
equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53. Testing performed under
standard laboratory conditions, actual performance may vary.
RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVAL:
Note: Depending on incoming feed water conditions replacement time frame may vary.
Description
Part
Number
Change
Time
Frame
Stage 1: sediment:
105311
6 Months
Stage 2: Lead + VOC Block
105371
6 Months
Stage 3: UF Membrane
105321
12 Months