Drill a Hole for the Faucet in a Porcelain Sink

NOTICE

     For Marble Counter-tops, we recommend contacting a qualified contractor for drilling a hole in a 

marble counter-top.

Note:  Most sinks are predrilled with 1½” or 1¼” diameter hole that you can use for your Drinking Water faucet. 

(If you are already using it for a sprayer or soap dispenser, see Step 1).

NOTICE

     Porcelain sinks are extremely hard and can crack or chip easily.  Use extreme caution when 

drilling.  Watts accepts no responsibility for damage resulting from the installation of faucet. 

Diamond tip bit recommended.

Step 1:   

 Determine desired  location  for  the faucet on your sink and place a piece 

of masking tape over where the hole is  to be drilled.  Mark the center of 

the hole on the tape.

Step 2  : 

 Using a variable speed drill set on the slowest speed, drill a 1/8“ pilot hole 

through both porcelain and metal casing of sink at the marked center of  

the desired location. Use lubricating oil or liquid soap to keep the drill bit  

cool (If drill bit gets hot it may cause the porcelain to crack or chip). 

Step 3:   

 Using a 1/2” diamond tip hole saw, proceed to drill the large hole.  Keep 

drill speed on  the  slowest speed and use lubricating oil or liquid soap to 

keep the hole saw cool during cutting.

Step 4:  

 After drilling, remove all sharp edges and make sure the surroundings of 

the sink are cooled before mounting  the faucet.

Or Punch a Hole for the Faucet in a Stainless Steel Sink

NOTICE

     If mounting faucet to a Stainless Steel Sink you will need a 1⁄2” Hole Punch. The faucet opening 

should be centered between the back splash and the edge of the sink, ideally on the same side 

as the vertical drain pipe.

Step 1:  

 Drill a ¼” pilot hole. Use a 1⁄2” Hole Punch and an adjustable wrench to 

punch the hole in the sink. 

Step 2:  

The Faucet can now be installed

Содержание Filter Pure UF3

Страница 1: ...uture reference WARNING Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system If you are unsure about installing your WA...

Страница 2: ...mbrane filtration process which uses standard home water pressure to push water through its semi permeable membrane Suspended particles and materials of high molecular weight are unable to pass throug...

Страница 3: ...agram 5 Drill a Hole for the Faucet in a Porcelain Sink 6 Or Punch a Hole for the Faucet in a Stainless Steel Sink 6 Faucet Installation 7 Adapt a Valve Installation 8 Green Tube Connection 8 Mounting...

Страница 4: ...0 5 gpm 60 psi Contents of Under Counter System Please make sure all of the items listed below are contained in the box If any of the items are missing please contact Watts Premier at 800 752 5582 pri...

Страница 5: ...e tube to check that it is secure It is a good practice to test the system prior to leaving the site and or before use To disconnect ensure the system is depressurized before removing the tube Push in...

Страница 6: ...lowest speed drill a 1 8 pilot hole through both porcelain and metal casing of sink at the marked center of the desired location Use lubricating oil or liquid soap to keep the drill bit cool If drill...

Страница 7: ...eeve small tapered end of sleeve must point to the end of tube and then insert the plastic insert all the way into the end of the tube Step 9 Push the assembled tube into the threaded stem until it st...

Страница 8: ...connect fitting located behind the Sediment filter Make sure to push the tube in all the way to the tube stop Step 15 Take the other end of the 1 4 Green tube and insert into the 1 4 quick connect fit...

Страница 9: ...nstallation of your new water filtration system Please Follow the Startup Instructions Step 1 Turn on water supply at angle stop and open the Adapt a Valve Turn faucet handle to the open position to s...

Страница 10: ...a towel under the filter module to catch any excess water that may drip out from the filters during the changeover Step 2 To remove a filter cartridge Push hold the button on the valved head above th...

Страница 11: ...0 08 0 001 CIS 1 3 DICHLOROPROPYLENE 99 0 079 0 001 Performance Data Sheet Watts Premier 8716 W Ludlow Drive Suite 1 Peoria AZ 8538 Model Filter Pure UF3 GENERAL USE CONDITIONS 1 Do not use with wate...

Страница 12: ...ZENE see CHLOROBENZENE 99 0 077 0 001 PCE see TETRACHLOROETHYLENE 99 0 081 0 001 PENTACHLOROPHENOL 99 0 096 0 001 PERCHLOROBUTADIENE see HEXACHLOROBUTADIENE 98 0 044 0 001 PROPYLENE DICHLORIDE see 1 2...

Страница 13: ...mber _______________ Serial Number _______________ Date of Install _________________ Installed by __________________ Date Sediment Filter 6 Months Carbon Block 6 Months UF Membrane 12 Months Date Sedi...

Страница 14: ...water to the Counter Top cannot exceed 100 degrees F 38 degrees C This warranty does not cover any equipment that is relocated from the site of its original installation This warranty does not cover a...