Display mode control
Fn_36 : Numbers of motor poles = 2 - 8 poles
Fn_47 = xxx0 : Output voltage display (Vac)disable;
xxx1 : enable
xx0x : DC voltage display (Vpn)disable;
xx1x : enable
x0xx : Output current (Iac)disable;
x1xx : enable
Fn_51 = 0: Display frequency(Hz); display preset frequency during stop mode and operation
frequency during run mode.
1. Display RPM of motor; numbers of poles set by Fn_36.
2. Line speed display mode: in integral (xxxx)
3. Line speed display mode: in one digit decimal (xxx.x)
4. Line speed display mode: in two digits decimal (xx.xx)
5. Line speed display mode: in three digits decimal (x.xxx)
Fn_52 = Line speed display in accordance with maximum output frequency (Fn_06)
120
freq.
(RPM) = x frequency ; Line speed =
x Fn_52 (decimal digits
Fn_36
Fn_06
decided by Fn_51)
DSP
Contents of display can be switched by FUN key either in run mode or stop mode.
Frequency/ RPM / Line speed ( mode set by Fn_51)
Fxxx
(Parameters setting mode: refer to digital operator illustration)
Output voltage
DC voltage
(output voltage, and DC voltage
output
current,
decided
by
Fn_47)
Output
current
Fn_37 - Fn_41 : Please refer to Fn_05
Fn_42 : Start frequency adjustment = 0.1 - 10 Hz