Service Procedures
•
Replacing Components
Watkiss Automatic SpineMaster Service Manual - Edited 17/06/04
4
-
37
Note: On the front of the Sensor Housing is a rectangular emitter/sensor win-
dow. The Sensor will work best if this window is in a horizontal posi-
tion. As the window will not be visible after fitting, mark the Sensor
Housing clearly to show the correct position.
13. Thread the Sensor Cable into position and connect to the PCB. Ensure that
there is just enough slack at the PCB end to prevent stress on the connec-
tion. Fasten cable ties.
14. Insert the Sensor through the Motor Mounting Plate and Mounting Brack-
et.
15. Secure the Mounting Bracket to the Motor Mounting Plate and check the
Sensor Position (see 4.7.4).
16. Replace the Book Deflector Plate and secure.
17. Replace the Side Covers and close the Top Delivery Assembly.
18. Reconnect mains power and test.