4 - 6
Watkiss Automatic SpineMaster Service Manual - Edited 17/06/04
Service Procedures
•
Removing Components
will reset the Clamp. Switch off the power and disconnect the mains input
lead.
WARNING
Always ensure that the ASM is switched off and disconnected from the mains
power supply before continuing to work inside.
6. Reach in through the aperture in the side frame and manually swivel the
Stop Assembly away from the booklet (see Figure 4:6). Remove the book-
let from the machine.
7. Replace the Side Covers.
8. Reconnect the mains power supply and test the machine is operating cor-
rectly.
4.6 Removing Components
4.6.1 Removal of the ASM Infeed Assembly
1. Open the Top Delivery Assembly.
2. Lift the Stacker Assembly to give internal access to the ASM
PARTS REQUIRED
TOOLS REQUIRED
None
3mm Allen Key
4mm Allen Key
Figure 4:6 Stop Assembly
Stop Assembly
Jammed Booklet
Figure 4:7 ASM access
Stacker Assembly