2 - 4
Watkiss Automatic SpineMaster Service Manual - Edited 17/06/04
Status Indicator RAPs
•
Error Indicator RAP
2.3 Error Indicator RAP
The machine will not run and the Error Indicator Light is illuminated.
Is there a booklet
jammed inside the
ASM?
Is LED9* (Guard)
illuminated?
Check/Replace
PCB 900-197.
Close the Guards.
Are the Guards
properly closed?
No
Check the Guard
Switch and wiring.
Remove the
jammed booklet. If
the problem per-
sists go to the
Jammed Booklet
Does LED10/11*†
illuminate when a
booklet is pushed
into the Infeed?
Check/replace
Infeed Sensor (see
Does LED15* illu-
minate when a
booklet is on the
Clamp Stop?
Check/replace
Clamp Optical
Yes
No
Yes
No
Yes
Yes
No
Yes
No
*on PCB 900-197
† LED10 for ASM & ASMN
LED11 for ASMB & ASMD