9
Normal Operation
1.
Home Display
a. Alternates between the display of Time of Day and Number of Days until the Next Backwash.
(Metered Softeners will alternate between time of days and gallons remaining until next
regeneration)
- Days Remaining until the Next Backwash will count down from the entered value until it
reaches 1 day remaining.
- A Backwash Cycle will then be initiated at the next designated regeneration time.
2.
Battery Back-Up
(Uses a standard 9-volt alkaline battery.)
Features of Battery Back-Up:
• During power failures, the battery will maintain the time of day as long as the battery has
power. The display is turned off to conserve battery power during this time. To confirm
that the battery is working, press either button and the display will turn on for five (5)
seconds.
• If power failure occurs while system is regenerating, the valve
will motor to a shut off posi
tion to prevent constant flow to drain. Depending
upon system pressure and other factors,
it is possible to observe a reduced flow to drain during this step. After power is restored,
the valve will return and finish the cycle where it left off prior to the power interruption.
• When used without battery back-up, during a power failure, the unit stops at its current
point in the regeneration position and then restarts at that point when the power is re
stored. The time will be offset by the increment of time the unit was
without power, so it is
necessary to reset the time of day on the unit. No other system will be affected.
Starting Extra Regeneration Cycle
1. To Start
Delayed Extra Cycle
Example ( 1 )
If Days Remaining Until Next Backwash does not read ‘1’, press and hold the
Set/Change
button for
3 seconds until the display reads ‘1’.
-
Backwash cycle will initiate at the next designated backwash time.
2. To start
Immediate Extra Cycle
First complete above step.
-
With Days Remaining Until Next Regeneration at ‘1’.
-
Press and hold the
Set/Change
button.
-
After 3 seconds, the backwash cycle will begin.
3. To
Fast Cycle
thru regeneration
First complete above 2 steps.
Note
:
Press and hold the
Set/Change
button for 3 seconds to advance to the next cycle step.
Fast Cycle is not necessary unless desired to manually step through each cycle step.
(Repeat until valve returns to the home display)
Programming the Control Valve
5. To Exit Main Menu, press the
Menu/Enter
button.
Note:
If no buttons are pressed for 60 seconds, the Main Menu will be exited automatically.