-PROVECTR Plus Location / Other Requirements-

• Locate the filter near a 120 volt / 60 Hz grounded electrical outlet.

• Check for distance and proper drain installation (e.g. floor drain, washing machine standpipe).

• Determine type and size of piping required for PROVECTR connection (e.g. galvanized, PVC plastic).

Note: 

If household plumbing is galvanized and you intend to make an installation with copper (or vice ver

            sa), obtain di-electric unions to prevent dissimilar metal corrosion.

Note: 

Where the drain line is elevated above the control valve or exceeds 20' in length to reach the drain, 

            use 3/4" I.D. drain line tubing instead of 1/2" I.D. Drain line tubing is not included.

Caution:

 When sweat soldering copper pipe (remember to always use lead free solder and flux), bypass 

                 valve with wet rags to prevent heat damage to connections and control valve! If using PVC or plas

                 tic pipe, primers and solvent cements specifically recommended for use with potable water are 

                 required. 

Note: 

All plumbing lines not requiring “filtered” water should be connected “upstream” of the A/P Tank. 

          (See Typical Installation Diagram.)

-Installation Procedure-

Caution: 

Raised arrows located on the sides of control valve body and bypass valve indicate proper direc

                 tion of water flow. Install inlet and outlet piping in direction of arrows. It is recommended that a 

                 vacuum breaker be installed on the inlet plumbing.

1. Position AP tank and Filter tank at the desired location.  The AP tank must be installed between the 

    pump/pressure tank and filter tank.  If a water softener is to be installed, it should be positioned after the

    filter tank.  

2. The filter media is shipped separately from the filter tank and should be loaded prior to installation.

 

a) Remove control valve by unscrewing it from the filter tank.

 

b) Plug distributor with cap provided to prevent any media from entering the inside of the tube.

 

c) Place media funnel onto tank and fill tank 1/3 with water

 

d) Pour in media.  Never fill tank more than 2/3 full to allow room for backwash.  Since the Provectr 

                  comes with a Vortech tank, gravel is NOT needed.

 

e) Remove cap and replace control valve.  

3. Turn off main water supply and open nearest faucet to relieve pressure.

4. Cut main line and install the AP tank and Filter tank.

5. Turn on main water supply and allow water to flow through new plumbing and keep the nearest faucet 

    open to evacuate air.

6. Check for leaks.

7. If no leaks, proceed by slowly opening the bypass and allow water to fill the filter tank.

8. Allow water to run through the filter for a few minutes and then turn off the nearest faucet.

Installation

Содержание Provectr Plus AF10AC-3

Страница 1: ...Provectr Plus Installation Operation Manual...

Страница 2: ...Assembly Page 17 Service Instructions Page 18 Troubleshooting Page 19 Error Codes Page 20 Warranty Information Page 21 FCC Compliance Statement http www chandlersystemsinc com files FCC_Compliance_St...

Страница 3: ...wn through the mineral bed of the filter and out the service lines The collected precipitates must be regularly removed from the filter by reversing the flow of water through the filter running to dra...

Страница 4: ...will notice an 8 foot meter cord and plug attached Note If household plumbing is galvanized and you intend to make an installation with copper or vice ver sa obtain dielectric unions to prevent dissi...

Страница 5: ...ypass valve indicate proper direc tion of water flow Install inlet and outlet piping in direction of arrows It is recommended that a vacuum breaker be installed on the inlet plumbing 1 Position AP tan...

Страница 6: ...soaked while preparing the installation and will pre vent the control valve from being plugged with floating material on initial backwash H Remove funnel and clean filter material from tank threads I...

Страница 7: ...ou hear and feel the O Ring pop into place before inserting the clip 2 Install 1 2 I D drain line tubing not included from hose barb to an open drain A 4 gap between end of the drain line and the open...

Страница 8: ...cal supply to be certain the cord is connected to an uninterrupted 115 volt outlet 3 REGISTER YOUR PRODUCT at www watersoftinc com 4 Leave this manual with the homeowner Important Notice The plumbing...

Страница 9: ...eft off prior to the power interruption When used without battery back up during a power failure the unit stops at its current point in the regeneration position and then restarts at that point when t...

Страница 10: ...th the Menu Enter button After the entire display flashes press the Menu Enter button to move to the next menu item 2 Regeneration Cycle Step Times Steps 1 2 3 4 Example 3 10 The next 4 displays set t...

Страница 11: ...the default password the first time you connect to it the app will ask you to enter the password After entering it the first time you should not need to enter it again unless it changes 3 BTLE Valve d...

Страница 12: ...ms in ORANGE with a set button can be changed For Filters Set Backwash Frequency This sets the amount of day between backwash cycles Change Time of Day Press SET to set time automatically based on dev...

Страница 13: ...p Option 2 Touch any graph to enlarge and see details Enlarged graphs are able to be zoomed in by pinching with two fingers Enlarged graph shown below Regenerate Unit at Next Regen Time button This wi...

Страница 14: ...Encoder 20001X124 1 3 Front Plate 20001X004 1 4 Encoder Wheel 20001X007 1 5 Main Gear 21001X120 1 6 Power Supply 20001X125 1 7 Back Plate 20001X005 1 8 Lower Front Base For Cover 20111X002 1 9 Motor 2...

Страница 15: ...15 Valve Body Drive Assy 2 1 3 18 19 28 12 17 16 4 8 9 10 11 14 15 13 24 20A 20B 26 27 21 25 22 16 23 5 7 6 6 6 6A...

Страница 16: ...5 1 12 10 24 X 1 Screw SST 20001X226 2 13 3 8 Push Lock Plug 20009X010 1 14 Injector Cap 20009X001 1 15 Injector Seal 20001X224 1 16 Injector Plug O Ring Assy 20001X217 1 17 Injector Screen 20001X222...

Страница 17: ...its 20017X284 3 1 Female Straight Slip Set optional 20017X288 4 1 NPT Straight Set optional 20017X289 5 3 4 NPT Straight Set optional 20017X307 6 1 X 3 4 Brass Sweat Connector Set optional 20017X304 7...

Страница 18: ...cover C To Replace Piston Assembly 1 Follow steps A1 A3 2 Disconnect the meter signal wire from the circuit board 3 Remove lower back base screws and detach lower back base 4 Remove screw and washer...

Страница 19: ...als Replace motor if motor is unresponsive F To Replace Meter 1 Follow steps A1 A3 2 Unplug meter cable from front of circuit board 3 Unscrew meter assembly nut from valve body 4 Remove meter from val...

Страница 20: ...wheel for debris 2 Cycle power Valve should either find home or go to a different error code If error 4 returns replace powerhead assembly Error 5 Motor overload This occurs when the motor current is...

Страница 21: ...charges service charges delivery expenses property damage administrative fees or any costs incurred by the purchaser in removing or reinstalling the water treatment equipment The Warranty does not cov...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...24 710 Orange Street Ashland OH 44805 PH 419 289 1500 FAX 419 289 1515 www watersoftinc com 0922TV...

Отзывы: