background image

11

 

 

                                                                                                                                                   

                                                                                                                                         

 

 

                                                                                                                                                   

                                                                                                                                         

For simplified set up and control, please install the Legacy View  on a compatible Bluetooth 4.0+ enabled 

smart phone or tablet.

1. Download and install the Legacy View app from the Google Play Store, Apple App Store 

2. Open the Legacy View app

 

• Choose a valve device at any time from the list of available devices to connect to by clicking on it.

 

• If the valve you want to connect to doesn’t show up, or there is a problem connecting to a device 

                you can press the “Scan for Devices” button or the Legacy View logo at any time to refresh the list

                and start the process over.

 

• If the valve device is a BTLE valve and it has a password other than the default password, the first 

                time you connect to it the app will ask you to enter the password. After entering it the first time 

                you should not need to enter it again unless it changes.

3. BTLE Valve devices can be updated by the App.  When the app is updated from the Google Play Store or 

    the Apple App Store, it may contain an updated firmware program for the valve devices. These updates 

    could contain new features or operational improvements. It is up to the user to allow these updates to be

    sent to the valve device. Uploading a new program takes approximately 1 minute. 

Dashboard

NOTE: Consult your dealer before making any changes

From the 

Dashboard

, all items in 

ORANGE

 can be changed, while blue fields are informational only. 

  

If you are unsure about the function of the field click the         for more information. 

Utilizing Bluetooth Control 

Содержание Provectr Plus AF10AC-3

Страница 1: ...Provectr Plus Installation Operation Manual...

Страница 2: ...Assembly Page 17 Service Instructions Page 18 Troubleshooting Page 19 Error Codes Page 20 Warranty Information Page 21 FCC Compliance Statement http www chandlersystemsinc com files FCC_Compliance_St...

Страница 3: ...wn through the mineral bed of the filter and out the service lines The collected precipitates must be regularly removed from the filter by reversing the flow of water through the filter running to dra...

Страница 4: ...will notice an 8 foot meter cord and plug attached Note If household plumbing is galvanized and you intend to make an installation with copper or vice ver sa obtain dielectric unions to prevent dissi...

Страница 5: ...ypass valve indicate proper direc tion of water flow Install inlet and outlet piping in direction of arrows It is recommended that a vacuum breaker be installed on the inlet plumbing 1 Position AP tan...

Страница 6: ...soaked while preparing the installation and will pre vent the control valve from being plugged with floating material on initial backwash H Remove funnel and clean filter material from tank threads I...

Страница 7: ...ou hear and feel the O Ring pop into place before inserting the clip 2 Install 1 2 I D drain line tubing not included from hose barb to an open drain A 4 gap between end of the drain line and the open...

Страница 8: ...cal supply to be certain the cord is connected to an uninterrupted 115 volt outlet 3 REGISTER YOUR PRODUCT at www watersoftinc com 4 Leave this manual with the homeowner Important Notice The plumbing...

Страница 9: ...eft off prior to the power interruption When used without battery back up during a power failure the unit stops at its current point in the regeneration position and then restarts at that point when t...

Страница 10: ...th the Menu Enter button After the entire display flashes press the Menu Enter button to move to the next menu item 2 Regeneration Cycle Step Times Steps 1 2 3 4 Example 3 10 The next 4 displays set t...

Страница 11: ...the default password the first time you connect to it the app will ask you to enter the password After entering it the first time you should not need to enter it again unless it changes 3 BTLE Valve d...

Страница 12: ...ms in ORANGE with a set button can be changed For Filters Set Backwash Frequency This sets the amount of day between backwash cycles Change Time of Day Press SET to set time automatically based on dev...

Страница 13: ...p Option 2 Touch any graph to enlarge and see details Enlarged graphs are able to be zoomed in by pinching with two fingers Enlarged graph shown below Regenerate Unit at Next Regen Time button This wi...

Страница 14: ...Encoder 20001X124 1 3 Front Plate 20001X004 1 4 Encoder Wheel 20001X007 1 5 Main Gear 21001X120 1 6 Power Supply 20001X125 1 7 Back Plate 20001X005 1 8 Lower Front Base For Cover 20111X002 1 9 Motor 2...

Страница 15: ...15 Valve Body Drive Assy 2 1 3 18 19 28 12 17 16 4 8 9 10 11 14 15 13 24 20A 20B 26 27 21 25 22 16 23 5 7 6 6 6 6A...

Страница 16: ...5 1 12 10 24 X 1 Screw SST 20001X226 2 13 3 8 Push Lock Plug 20009X010 1 14 Injector Cap 20009X001 1 15 Injector Seal 20001X224 1 16 Injector Plug O Ring Assy 20001X217 1 17 Injector Screen 20001X222...

Страница 17: ...its 20017X284 3 1 Female Straight Slip Set optional 20017X288 4 1 NPT Straight Set optional 20017X289 5 3 4 NPT Straight Set optional 20017X307 6 1 X 3 4 Brass Sweat Connector Set optional 20017X304 7...

Страница 18: ...cover C To Replace Piston Assembly 1 Follow steps A1 A3 2 Disconnect the meter signal wire from the circuit board 3 Remove lower back base screws and detach lower back base 4 Remove screw and washer...

Страница 19: ...als Replace motor if motor is unresponsive F To Replace Meter 1 Follow steps A1 A3 2 Unplug meter cable from front of circuit board 3 Unscrew meter assembly nut from valve body 4 Remove meter from val...

Страница 20: ...wheel for debris 2 Cycle power Valve should either find home or go to a different error code If error 4 returns replace powerhead assembly Error 5 Motor overload This occurs when the motor current is...

Страница 21: ...charges service charges delivery expenses property damage administrative fees or any costs incurred by the purchaser in removing or reinstalling the water treatment equipment The Warranty does not cov...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...24 710 Orange Street Ashland OH 44805 PH 419 289 1500 FAX 419 289 1515 www watersoftinc com 0922TV...