F-1031, Section 3028
Page 2 of 37
!
WARNING
Death or serious personal injury might occur if proper operating procedures
are not followed. The pump operator, as well as individuals connecting
supply or discharge hoses to the apparatus must be familiar with these
pump operating instructions as well as other operating instructions and
manuals for the apparatus, water hydraulics and component limitation.
!
WARNING
Scalding Water Hazard. May result in serious burns.
When operating the pump, be sure to open at least one discharge valve
slightly to prevent the pump from overheating. If the pump runs for a few
minutes completely closed, it may heat the water enough to scald someone
when the valve is opened. Overheating can damage the packing, seals
and other pump parts. If the apparatus builder has installed a by-pass sys-
tem or other provision designed to prevent overheating, opening a dis-
charge valve may be unnecessary.
Safety Information
Introduction
M
This instruction covers the installation of a Waterous Eclipse
Read through and communicate safety information to the
tem. The Eclipse ES consists of a Waterous CX Series fire pump, C20 trans-
mission and an oil-flooded rotary screw compressor. The Eclipse
ES is ca-
end user of this Waterous Fire Pump.
pable of up to 1250 GPM (4750 L/min) of water and 200 CFM (5.6 m
3
/min) of
air.
"TM
Figure 1. Eclipse
ES
The following installation instructions are available:
•
CX Pump Installation, F-1031, Section 3014
•
Priming System, F-1031, Section 3023
•
Manifold Drain Valves, F-1031, Section 3008
•
Overheat Protection Manager (OPM), F-1031, Se
M
ction 3015
Before proceeding with the installation of the Eclipse
ES, read the following
instructions carefully. Check the appropriate dimensional drawings in the Engi-
neering Manual as needed.
CAUTION
Operating Speed Limit.
May cause damage to the pump and/or air compressor.
The Eclipse compressor has a maximum operating speed of 8950 RPM.
Do not allow the compressor to run beyond 8950 RPM.
Compressor speed can be calculated by
(Engine Speed) x (Pump Trans-
mission Ratio) x 2.5.
!
WARNING
Compressed Air Pressure Hazard. May result in personal injury.
Compressed air can be dangerous. Make sure the pressure is allowed to
bleed down to atmospheric pressure prior to opening any connections or
valves.
!
WARNING
Pressure Hazard. May result in personal injury.
Prior to connection or removal of hoses, caps or other closures with pump
intake or pump discharge connections, relieve pressure by opening drains
or bleeder valves. Bleeder valves should also be used while filling a hose
connected to an intake with water.
NOTICE
Содержание Eclipse ES
Страница 4: ...F 1031 Section 3028 Page 4 of 37 Items Shipped Loose IIL Components See Page 3 for Details IL300 6 ...
Страница 5: ...F 1031 Section 3028 Page 5 of 37 Installation Mounting Clearances Required for Maintenance ...
Страница 7: ...F 1031 Section 3028 Page 7 of 37 ...
Страница 8: ...F 1031 Section 3028 Page 8 of 37 ...
Страница 10: ...F 1031 Section 3028 Page 10 of 37 Oil Sump and Oil Temperature Sensor ...
Страница 11: ...F 1031 Section 3028 Page 11 of 37 Air Oil Separator ...
Страница 15: ...F 1031 Section 3028 Page 15 of 37 Compressor Air Connections ...
Страница 16: ...F 1031 Section 3028 Page 16 of 37 Air Clutch Connection ...
Страница 18: ...F 1031 Section 3028 Page 18 of 37 Water Drains ...
Страница 19: ...F 1031 Section 3028 Page 19 of 37 Lubrication ...
Страница 20: ...F 1031 Section 3028 Page 20 of 37 Electrical Wiring ...
Страница 21: ...F 1031 Section 3028 Page 21 of 37 Power to Compressor Relay Panel Air Clu ...
Страница 22: ...F 1031 Section 3028 Page 22 of 37 ...
Страница 25: ...F 1031 Section 3028 Page 25 of 37 ...
Страница 26: ...F 1031 Section 3028 Page 26 of 37 ...
Страница 27: ...F 1031 Section 3028 Page 27 of 37 ...
Страница 28: ...F 1031 Section 3028 Page 28 of 37 Oil Temperature ...
Страница 32: ...F 1031 Section 3028 Page 32 of 37 Calibration ...
Страница 34: ...F 1031 Section 3028 Page 34 of 37 Control Air Circuit Component Locations ...