F-1031, Section 3028
Page 30 of 37
Suggested for 1-1/2" and 2" Discharges - Use 1/2" Air Hose
Suggested Fittings for Auxiliary Air Outlet - Use 3/8" Air Hose
Quantity
Description
1
38 BV Class 1 Valve
1
Class 1 #102089 Gauge Test Plug for Auxiliary Air
Quantity
Fittings Per Discharge
4
#6 JIC x 6 Push-Lock
2
#6 JIC x
1/2” NPT-M 90
1
#6 JIC x 1/4” NPT-M
If an electric solenoid valve is used for air instead of a manual valve, use:
•
1/2" direct-acting solenoid valve
•
Toggle switch SPST (suggest switch guard)
•
#8 x 1/2" Female 37 JIC swivel to NPT-M adapter
•
Delete #8 JIC x 8 Push-Lock
•
Delete #8 JIC x 1/2" NPT-M 90
Suggested for 2-1/2" Discharges - Use 3/4" Air Hose
NOTE: Fittings on all hoses should be 37 JIC.
Air Distribution Manifold
Waterous suggests NPT fittings with the appropriate number and size ports,
however, the manifold can be built with air brake tubing if strict attention is
paid to the inside diameters:
Quantity
Description
1
Water Check Valve
(wafer, flange or ball & cone style - same size as discharge)
1
34 BV90 Class 1 Valve
Quantity
Fittings Per Discharge
4
#12 JIC x 12 Push-Lock
2
#12 JIC x
1/2” NPT-M 90
1
#12 JIC x 3/4” NPT-M
1
3/4” NPT Nipple
1
3/4” Air Check Valve
If an electric solenoid valve is used for air instead of a manual valve, use:
•
1/2" or 3/4" direct-acting solenoid valve
•
Toggle switch SPST (suggest switch guard)
•
Proper size adapter
•
If 1/2" valve, use #8 x 1/2" Female 37 JIC swivel to NPT-M adapter
•
If 3/4" valve, use #12 x 3/4" Female 37 JIC swivel to NPT-M adapter
•
Delete #12 JIC x 12 Push-Lock
•
Delete #12 JIC x 1/2" NPT-M 90
Quantity
Description
1
Water Check Valve
(wafer, flange or ball & cone style - same size as discharge)
1
12 BV Class 1 Valve
Quantity
Fittings Per Discharge
4
#8 JIC x 8 Push-Lock
2
#8 JIC x
1/2” NPT-M 90
1
#8 JIC x 3/4” NPT-M
1
3/4” NPT Nipple
1
3/4” Air Check Valve
Air Brake Hose O.D. / I.D. Dimensions
O.D. (Inches)
I.D. (Inches)
.375
.250
.500
.375
.625
.500
.750
.625
Содержание Eclipse ES
Страница 4: ...F 1031 Section 3028 Page 4 of 37 Items Shipped Loose IIL Components See Page 3 for Details IL300 6 ...
Страница 5: ...F 1031 Section 3028 Page 5 of 37 Installation Mounting Clearances Required for Maintenance ...
Страница 7: ...F 1031 Section 3028 Page 7 of 37 ...
Страница 8: ...F 1031 Section 3028 Page 8 of 37 ...
Страница 10: ...F 1031 Section 3028 Page 10 of 37 Oil Sump and Oil Temperature Sensor ...
Страница 11: ...F 1031 Section 3028 Page 11 of 37 Air Oil Separator ...
Страница 15: ...F 1031 Section 3028 Page 15 of 37 Compressor Air Connections ...
Страница 16: ...F 1031 Section 3028 Page 16 of 37 Air Clutch Connection ...
Страница 18: ...F 1031 Section 3028 Page 18 of 37 Water Drains ...
Страница 19: ...F 1031 Section 3028 Page 19 of 37 Lubrication ...
Страница 20: ...F 1031 Section 3028 Page 20 of 37 Electrical Wiring ...
Страница 21: ...F 1031 Section 3028 Page 21 of 37 Power to Compressor Relay Panel Air Clu ...
Страница 22: ...F 1031 Section 3028 Page 22 of 37 ...
Страница 25: ...F 1031 Section 3028 Page 25 of 37 ...
Страница 26: ...F 1031 Section 3028 Page 26 of 37 ...
Страница 27: ...F 1031 Section 3028 Page 27 of 37 ...
Страница 28: ...F 1031 Section 3028 Page 28 of 37 Oil Temperature ...
Страница 32: ...F 1031 Section 3028 Page 32 of 37 Calibration ...
Страница 34: ...F 1031 Section 3028 Page 34 of 37 Control Air Circuit Component Locations ...