9
|
56
CM Series Pumps—Intake and Discharge Flanges
CM Series pumps are available with angle-compensated or non-angle-compensated front and side discharge flanges—pump without angle compensation shown
below. Pumps with angle compensation feature a front discharge flange angled at 4° and side discharge flanges with holes machined at a 4° rotation. This option
ensures that the discharges align with the operator panel after installation.
Feature
Feature
Description
Description
1 Center discharge flange
Water exits the pump through this discharge.
In applications where discharge plumbing is not needed, a cover is available.
2 Side discharge flange
Water exits the pump through the side discharges. Optional discharge fittings and plumbing are available to connect to the
discharge flanges.
3 Front discharge flange
Water exits the pump through this discharge. In applications where discharge plumbing is not needed, a cover is available.
4 Intake flange
Water enters the pump through the intakes. Optional intake fittings are available to connect to the intake flanges.
5 Tank-to-pump flange
This is where the tank-to-pump valve or fitting is mounted on the pump.
6 Priming valve mounting pad
This is where the priming valve is mounted on the pump. In applications without a priming valve, a cover is available.
4
4
3
2
1
6
2
5