SECTION 10. INITIAL POWER-UP
A. Post-Installation, Pre-Power up Safety Check
Before you power-up the Waterous system:
1. Remove all tools, shop towels, hose trimmings and other debris from the
compartments.
2. Double-check all hydraulic, air and water lines against the schematics, testing to
make sure each connection is tight and that the hose is fully inserted into the fitting.
3. Check all of the unused inlets: plastic shipping caps must be removed and replaced
with the appropriate plug or cap.
4. Make sure all drain valves are closed.
6. Make sure the gauges are connected to the appropriate sender (temperature,
pressure, etc.)
7. Fill the sump with the specified hydraulic oil until the oil level is 1/2 way up the sight
glass. You will need to add more oil later, to compensate for oil that remains in the
hydraulic lines and the compressor.
8. Oil used in the system is ISO 68wt hydraulic oil. It must be "Low-foaming" or "Anti-
foam".
7. Make sure the foam proportioner is operating properly. (see the manufacturer's
installation guide).
8. Make sure the fire pump is operating properly and that water flows through the oil
cooler.
B. Initial Compressor System Power-up
Warning:
Compressed air can be dangerous. Make sure the pressure is allowed to bleed
down to atmospheric pressure before opening any connections or valves.
1. Remove the air filter plumbing and pour 8 to 16 ounces of hydraulic oil into the air
inlet of the compressor.
2. Replace the air filter plumbing.
3. Place the Auto-Sync system in UNLOAD and AUTO (UNLOAD for electric Auto-
Sync)
4. Start the vehicle's engine and engage the compressor system.
Содержание 200-B
Страница 39: ...Waterous 200 B Belt Driven Installation Guide Rev Page 39 of 54 Figure 33 Basic CAFS System...
Страница 40: ...Waterous 200 B Belt Driven Installation Guide Rev Page 40 of 54 Figure 34 200 B with T Sump...
Страница 41: ...Waterous 200 B Belt Driven Installation Guide Rev Page 41 of 54 Figure 35 200 B with Vertical Sump...
Страница 42: ...Waterous 200 B Belt Driven Installation Guide Rev Page 42 of 54 Figure 36 Compressor Dimensions...
Страница 43: ...Waterous 200 B Belt Driven Installation Guide Rev Page 43 of 54 Figure 37 T Sump Dimensions...
Страница 44: ...Waterous 200 B Belt Driven Installation Guide Rev Page 44 of 54 Figure 38 10 Vertical Reservoir...
Страница 45: ...Waterous 200 B Belt Driven Installation Guide Rev Page 45 of 54 Figure 39 Oil Cooler...
Страница 46: ...Waterous 200 B Belt Driven Installation Guide Rev Page 46 of 54 Figure 40 200 B Oil and Separator...
Страница 47: ...Waterous 200 B Belt Driven Installation Guide Rev Page 47 of 54 Figure 41 Separator Bracket...
Страница 48: ...Waterous 200 B Belt Driven Installation Guide Rev Page 48 of 54 Figure 42 Hydraulic Schematic with T Sump...
Страница 50: ...Waterous 200 B Belt Driven Installation Guide Rev Page 50 of 54 Figure 44 Electrical Schematic for Auto sync...