background image

 

 

TABLE OF CONTENTS 

 

Preinstallation instructions for dealer 

Inside front cover 

Specifications 

Cycle  sequence  settings 

Softener  System Setup (programming) 

4-6 

Bypass  valve  description  & diagrams 

Installation 

8-9 

Installer settings 

 

Hardness, Override, Regen Time & Time of Day 

10 

Normal  operating & error displays,  power loss 

11 

Low salt warning & resetting it 

12 

Start- up  instructions 

13 

Replacement parts & valve repair 

 

Front Cover, Drive Assembly and Piston 

14 

Injector assembly & refill port assembly 

15 

Drain  line  3/4"  assembly  & flow  controls 

16 

Drain  line  1"  assembly  &  flow  controls 

17 

Water  meter  &  bypass  valve 

18 

Installation fitting assemblies & service wrench 

19 

Control  valve  servicing 

20-24 

Troubleshooting  procedures 

25-26 

 

 

 

PREINSTALLATION INSTRUCTIONS 

This unit has a control valve which enables the setting of not only the length of each regeneration cycle but also the order 

in which cycles (steps of regeneration) occur. The following pages instruct how to set the treatment unit’s sequence of 

cycles, cycle times, salt dose, exchange capacity, and gallon capacity/regeneration time. A salt warning option may also 

be included. 

 

 

THE DEALER... 

1.  Read this page, GENERAL INSTRUCTIONS, INSTALLER SETTINGS, NORMAL OPERATING DISPLAYS, and 

LOW SALT WARNING. 

2.  Complete the CYCLE SEQUENCE SETTINGS. 

3.  Complete the SOFTENER SYSTEM SETUP.  

a.  Cycle Times 

b.  Choose Softener or Filter  

c.  Set Salt Dose 

d.  Set Capacity 

e.  Set How Gallon Capacity Will be Calculated  

f.  Set Regeneration Time Option 

g.  Select or Turn Off Low Salt Warning 

 

 

THE INSTALLER... 

1.  Read Bypass Valve page. 

2.  Read GENERAL INSTRUCTIONS, NORMAL OPERATING DISPLAYS, and RESETTING LOW SALT WARNING 

(if applicable). 

3.  Be sure CYCLE SEQUENCE SETTINGS and SOFTENER SYSTEM SETUP are done before leaving for 

installation. 

4.  Follow INSTALLATION INSTRUCTIONS, INSTALLER SETTINGS, TIME OF DAY, and RESETTING SALT 

Содержание V3175-01

Страница 1: ...ENT FOR REFERENCE PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PRODUCT...

Страница 2: ...nly the length of each regeneration cycle but also the order in which cycles steps of regeneration occur The following pages instruct how to set the treatment unit s sequence of cycles cycle times sal...

Страница 3: ...potassium permanganate sodium hydroxide hydrochloric acid COMPATIBLE CHEMICALS sodium bisulfite sodium hydrosulfite chlorine chloramines GENERAL INSTRUCTIONS During operation the normal user displays...

Страница 4: ...Once the valve has completed the immediate regeneration the valve will regenerate one more time at the pre set regeneration time...

Страница 5: ...use the or button to display it Then press NEXT and again for 3 seconds and release If screen in Step 2CS does not appear in 5 seconds the lock on the valve is activated To unlock press NEXT and SET C...

Страница 6: ...p 4S Select the time for the second cycle which in this example is dn BRINE using the or button Press NEXT to go to Step 5S Press REGEN if you need to return to previous step NOTE The display will fla...

Страница 7: ...s using the button If value is set to NORMAL the regeneration will occur at the preset time on O the regeneration will occur immediately when the gallons capacity reaches 0 zero NORMAL on 0 the regene...

Страница 8: ...er of days between regenerations is reached AUTO On O oFF Reserve capacity automatically estimated Regeneration occurs immediately when gallons capacity reaches 0 Time of regeneration is not allowed t...

Страница 9: ...point to the center of the bypass The system is isolated from the water pressure in the plumbing system Untreated water is supplied to the building See Figure 2 3 Diagnostic Position The inlet handle...

Страница 10: ...ectrical Use a 115 120V 60Hz uninterrupted outlet Current draw is 0 5 amperes A 15 ft power cord is furnished The plug in transformer is for dry locations only Batteries are not used 1 The distance be...

Страница 11: ...h the drain connection on the control valve This will provide an adequate anti siphon trap Where the drain empties into an overhead sewer line a sink type trap must be used Run drain tube to its disch...

Страница 12: ...ion 1 to 28 default 14 or set to oFF Press NEXT to go to step 4I Press REGEN if you need to return to previous step STEP 4I Next Regeneration Time hour Set the hour of day for regeneration using or bu...

Страница 13: ...system runs through the steps automatically and will reset itself to provide treated water when the regeneration has been completed MANUAL REGENERATION Sometimes there is a need to regenerate before t...

Страница 14: ...remaining option is used the following steps must be completed Step 1US Press the NEXT button until SALT appears in the display It does not matter if the SALT display alternates with the LBS REMAININ...

Страница 15: ...dily to the drain without the presence of air restore power and momentarily press the REGEN button to advance the control to the BRINE position 5 Fully open the inlet bypass valve handle bypass is now...

Страница 16: ...2x36 3 6 V3109 Drive gear cover 1 2 6 V3002CC Drive assy CC not shown V3186 Transformer 110V 12V 1 5 3 Piston Assembly Item No Part No Description Qty 1 V3005 Spacer stack assy 1 2 V3004 Drive cap ass...

Страница 17: ...3010 1K K injector assy DARK GREEN not shown V3170 O ring 011 lower not shown V3171 O ring 013 upper The injector plug and the injector each use one lower and one upper o ring Note For a backwash only...

Страница 18: ...01 DLFC Retainer assy 1 7 V3162007 0 7 DLFC for elbow One DLFC must be used if fitting is used V3162010 1 0 DLFC for elbow V3162013 1 3 DLFC for elbow V3162017 1 7 DLFC for elbow V3162022 2 2 DLFC for...

Страница 19: ...105 O ring 215 1 9 V3190 065 6 5 gpm DLFC for 1 fitting One DLFC must be used if 1 fitting is used V3190 075 7 5 gpm DLFC for 1 fitting V3190 090 9 0 gpm DLFC for 1 fitting V3190 110 11 0 gpm DLFC for...

Страница 20: ...2 O ring 135 2 9 V3155 O ring 112 2 10 V3156 O ring 214 2 90 Vertical elbow adapter assy for bypass valve not shown Part No V319101 Part No Description Qty V3151 Nut 1 quick connect 2 V3150 Split ring...

Страница 21: ...V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 Description Fitting 1 Brass Sweat Assembly Assembly Part No V3007 02 2 req d Item No 4 Fitting only Part No V3188 2 req d Descript...

Страница 22: ...et to disengage the notches To reassemble seat the bottom of the drive bracket so the notches are engaged at the bottom of the drive back plate Push the top of the drive bracket towards the two latche...

Страница 23: ...s with an o ring To remove the drive cap assembly use the Service Wrench V3193 or insert a to 5 16 flat bladed screwdriver into one of the slots around the top 2 of the drive cap assembly so it engage...

Страница 24: ...of the assembly into the control valve body The assembly is properly seated when at least four threads are exposed approximately 5 8 Do not force the spacer stack assembly in The control valve body b...

Страница 25: ...ire visible then a plug should be found in the meter location With the nut removed a slot at the top of the water meter is visible Twist a flat blade screwdriver in the slot between the control valve...

Страница 26: ...lve caps Caution Since the handles can be pulled off they could be accidentally reinstalled 180 degrees from their correct orientation After completing any valve maintenance press and hold NEXT and RE...

Страница 27: ...ation d Control set at on 0 d Check with regen time option in programming e Control set at NORMAL on 0 e Check with regen time option in programming 5 ERROR followed by a code number ERROR code 1001 U...

Страница 28: ...unplugged a Connect transformer and PC board power b No power at outlet b Restore power c Broken drive gear or drive cap assembly c Replace gear or drive cap assembly d Defective PC board d Replace b...

Страница 29: ...WATERITE INC Winnipeg MB Canada www waterite com...

Отзывы: