SOFTENER SET UP DETAIL TABLE
This table is to be used as a guide or shortcut to the settings made in Step 3I, 8S, and 9S. For quick programming use the
recommended settings shown in row 3 below in bold italic type.
Gallons
Capacity
Regeneration
Time Option
Day
Override
Result
AUTO
NORMAL
oFF
Reserve capacity automatically estimated.
Regeneration occurs when gallons capacity falls below the reserve
capacity at the time.
AUTO
NORMAL
Any number
Reserve capacity automatically estimated.
Regeneration occurs at the next Regen. Set Time when gallons
capacity falls below capacity...or the specified number of days
between regenerations is reached.
Any
number
NORMAL
oFF
Reserve capacity not automatically estimated. Regeneration occurs at
the next Regen. or when gallons capacity reaches 0
oFF
NORMAL
Any number
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen. Set Time when the specified
number of da regenerations is reached.
Any
number
NORMAL
Any number
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen. Set Time when gallons
capacity reaches 0 number of days between regenerations is
reached
AUTO
On O
oFF
Reserve capacity automatically estimated.
Regeneration occurs immediately when gallons capacity reaches 0.
Time of regeneration is not allowed to be set because regeneration
will always occur when gallons capacity reaches 0.
Any
number
On O
oFF
Reserve capacity not automatically estimated.
Regeneration occurs immediately when gallons capacity reaches 0.
Time of regeneration is not allowed to be set because regeneration
will always occur.
AUTO
NORMAL on O
oFF
Reserve capacity automatically estimated.
Regeneration occurs when gallons capacity falls below the
reserve capacity at the Time or regeneration occurs immediately
after 10 minutes of no water usage when reaches 0.
AUTO
NORMAL on O
Any number
Reserve capacity automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons
capacity falls below capacity or the specified number of days
between regenerations is reached, or re immediately after 10 minutes
of no water usage when gallon capacity reaches 0.
Any
number
NORMAL on O
Any number
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when the
specified number of day regenerations is reached, or regeneration
occurs immediately after 10 minutes of when gallon capacity
reaches 0.