TROUBLESHOOTING PROCEDURES 1 

 

 

Problem 

Cause 

Solution 

1. Timer does not 

display time of day 

a. Transformer unplugged 

a. Reconnect transformer 

b. No power at outlet 

b. Repair or use working outlet 

c. Defective  transformer 

c. Replace transformer 

d. Defective PC board  

 

    

d. Replace PC board 

2. Timer does not 

display correct time 

of day 

a. Outlet is on a switch 

a. Use unswitched outlet 

b. Power outage 

b Reset time of day 

c. Defective PC board 

c. Replace PC board 

3. No 

softening/filtering 

display when water 

is flowing 

a. Bypass valve in bypass position 

a. Put bypass in Service position 

b. Meter cable disconnected 

b. Reconnect to PC board 

c. Restricted/stalled  meter  turbine 

c. Remove meter and check for debris 

d. Defective  meter 

d. Replace meter 

e. Defective PC board 

e. Replace PC board 

4. Unit regenerates at 

wrong time of day 

a. Past power outage 

a. Reset time of day 

b. Wrong time of day displayed 

b. Reset time of day 

c. Time of regeneration set wrong 

c. Reset time of regeneration 

d. Control set at "on 0" 

d. Check with regen time option in 

programming 

e. Control set at  on 0 

e. Check with regen time option in 

programming 

5. ERROR followed by 

a code number 

 

ERROR code 1001: 

Unable to recognize 

start  of 

regeneration 

 

ERROR code 1002: 

Unexpected stall 

 

ERROR code 1003: 

Motor ran too long. 

Timed out trying to 

reach next cycle 

position. 

 

If other codes appear 

contact factory 

a. Valve has just been serviced 

a. Press NEXT and REGEN for 3 

seconds or momentarily unplug power 

source from PC board 

b. Foreign material stuck in valve 

b. Check piston and spacer stack for 

obstruction 

c. Excessive piston resistance 

c. Replace piston(s) and spacer stack 

d. Piston not in home position 

d. Press NEXT and REGEN or 

momentarily unplug PC board power 

e. Motor gears not fully engaged. Motor wires 

broken. Failed motor. 

e. Check motor and wiring 

f. Center drive gear reflector dirty or 

damaged. Missing or broken gear. 

f. Replace or clean drive gear(s) 

g. Drive bracket incorrectly aligned on 

backplate 

g. Reset drive bracket 

h. PC board is damaged or defective 

h. Replace PC board 

i. PC board incorrectly aligned on drive 

bracket 

i. Reset PC board onto drive bracket 

 

 

 

 

 

 

 

 

 

 

 

Содержание V3175-01

Страница 1: ...ENT FOR REFERENCE PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PRODUCT...

Страница 2: ...nly the length of each regeneration cycle but also the order in which cycles steps of regeneration occur The following pages instruct how to set the treatment unit s sequence of cycles cycle times sal...

Страница 3: ...potassium permanganate sodium hydroxide hydrochloric acid COMPATIBLE CHEMICALS sodium bisulfite sodium hydrosulfite chlorine chloramines GENERAL INSTRUCTIONS During operation the normal user displays...

Страница 4: ...Once the valve has completed the immediate regeneration the valve will regenerate one more time at the pre set regeneration time...

Страница 5: ...use the or button to display it Then press NEXT and again for 3 seconds and release If screen in Step 2CS does not appear in 5 seconds the lock on the valve is activated To unlock press NEXT and SET C...

Страница 6: ...p 4S Select the time for the second cycle which in this example is dn BRINE using the or button Press NEXT to go to Step 5S Press REGEN if you need to return to previous step NOTE The display will fla...

Страница 7: ...s using the button If value is set to NORMAL the regeneration will occur at the preset time on O the regeneration will occur immediately when the gallons capacity reaches 0 zero NORMAL on 0 the regene...

Страница 8: ...er of days between regenerations is reached AUTO On O oFF Reserve capacity automatically estimated Regeneration occurs immediately when gallons capacity reaches 0 Time of regeneration is not allowed t...

Страница 9: ...point to the center of the bypass The system is isolated from the water pressure in the plumbing system Untreated water is supplied to the building See Figure 2 3 Diagnostic Position The inlet handle...

Страница 10: ...ectrical Use a 115 120V 60Hz uninterrupted outlet Current draw is 0 5 amperes A 15 ft power cord is furnished The plug in transformer is for dry locations only Batteries are not used 1 The distance be...

Страница 11: ...h the drain connection on the control valve This will provide an adequate anti siphon trap Where the drain empties into an overhead sewer line a sink type trap must be used Run drain tube to its disch...

Страница 12: ...ion 1 to 28 default 14 or set to oFF Press NEXT to go to step 4I Press REGEN if you need to return to previous step STEP 4I Next Regeneration Time hour Set the hour of day for regeneration using or bu...

Страница 13: ...system runs through the steps automatically and will reset itself to provide treated water when the regeneration has been completed MANUAL REGENERATION Sometimes there is a need to regenerate before t...

Страница 14: ...remaining option is used the following steps must be completed Step 1US Press the NEXT button until SALT appears in the display It does not matter if the SALT display alternates with the LBS REMAININ...

Страница 15: ...dily to the drain without the presence of air restore power and momentarily press the REGEN button to advance the control to the BRINE position 5 Fully open the inlet bypass valve handle bypass is now...

Страница 16: ...2x36 3 6 V3109 Drive gear cover 1 2 6 V3002CC Drive assy CC not shown V3186 Transformer 110V 12V 1 5 3 Piston Assembly Item No Part No Description Qty 1 V3005 Spacer stack assy 1 2 V3004 Drive cap ass...

Страница 17: ...3010 1K K injector assy DARK GREEN not shown V3170 O ring 011 lower not shown V3171 O ring 013 upper The injector plug and the injector each use one lower and one upper o ring Note For a backwash only...

Страница 18: ...01 DLFC Retainer assy 1 7 V3162007 0 7 DLFC for elbow One DLFC must be used if fitting is used V3162010 1 0 DLFC for elbow V3162013 1 3 DLFC for elbow V3162017 1 7 DLFC for elbow V3162022 2 2 DLFC for...

Страница 19: ...105 O ring 215 1 9 V3190 065 6 5 gpm DLFC for 1 fitting One DLFC must be used if 1 fitting is used V3190 075 7 5 gpm DLFC for 1 fitting V3190 090 9 0 gpm DLFC for 1 fitting V3190 110 11 0 gpm DLFC for...

Страница 20: ...2 O ring 135 2 9 V3155 O ring 112 2 10 V3156 O ring 214 2 90 Vertical elbow adapter assy for bypass valve not shown Part No V319101 Part No Description Qty V3151 Nut 1 quick connect 2 V3150 Split ring...

Страница 21: ...V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 Description Fitting 1 Brass Sweat Assembly Assembly Part No V3007 02 2 req d Item No 4 Fitting only Part No V3188 2 req d Descript...

Страница 22: ...et to disengage the notches To reassemble seat the bottom of the drive bracket so the notches are engaged at the bottom of the drive back plate Push the top of the drive bracket towards the two latche...

Страница 23: ...s with an o ring To remove the drive cap assembly use the Service Wrench V3193 or insert a to 5 16 flat bladed screwdriver into one of the slots around the top 2 of the drive cap assembly so it engage...

Страница 24: ...of the assembly into the control valve body The assembly is properly seated when at least four threads are exposed approximately 5 8 Do not force the spacer stack assembly in The control valve body b...

Страница 25: ...ire visible then a plug should be found in the meter location With the nut removed a slot at the top of the water meter is visible Twist a flat blade screwdriver in the slot between the control valve...

Страница 26: ...lve caps Caution Since the handles can be pulled off they could be accidentally reinstalled 180 degrees from their correct orientation After completing any valve maintenance press and hold NEXT and RE...

Страница 27: ...ation d Control set at on 0 d Check with regen time option in programming e Control set at NORMAL on 0 e Check with regen time option in programming 5 ERROR followed by a code number ERROR code 1001 U...

Страница 28: ...unplugged a Connect transformer and PC board power b No power at outlet b Restore power c Broken drive gear or drive cap assembly c Replace gear or drive cap assembly d Defective PC board d Replace b...

Страница 29: ...WATERITE INC Winnipeg MB Canada www waterite com...

Отзывы: