5
SOFTENER SYSTEM SETUP - continued
Step 8S – Set Gallons Capacity using the
button. If value is set to:
• “AUTO” ...the gallon capacity will be automatically calculated and reserve capacity will be
automatically estimated.
• “oFF”...the regeneration will be based on the day override set
(see Installer Settings Step 3I).
• a specific number (allowable range 20 to 50,000)...the regeneration initiation will be based
on the value specified. The settable increment is 20 for the range 20 to 1000, 50 for the range
of 1000 to 10,000 and 100 for the range of 10,000 to 50,000.
If “oFF” or a specific number is used, hardness display will not be allowed to be set in Installer
Displays Step 2I. Press NEXT to go to Step 9S. Press REGEN if you need to return to the
previous step.
Step 9S – Set Regeneration Time Options using the
button. If value is set to:
• “NORMAL”...the regeneration will occur at the preset time.
• “on O”...the regeneration will occur immediately when the gallons capacity reaches 0 (zero).
• “ on 0”...the regeneration will occur at one of the following:
— the preset time when the gallons capacity falls below the reserve or the specified number
of days between regenerations is reached whichever comes first; or,
— immediately after 10 minutes of no water usage when the gallon capacity reaches 0 (zero).
Press NEXT to go to Step 10S. Press REGEN if you need to return to the previous step.
Step 10S – Set Low Salt Warning using
button. If the value is set to:
• “oFF”...no low salt level warning will appear for the user.
• a specific value...“FILL SALT” will flash on the display when the calculated remaining
pounds of salt falls below that level. Allowable values range from
10 to 400 pounds in 10 pound increments.
Press NEXT to exit SOFTENER SYSTEM SETUP. Press REGEN
if you need to return to the previous step.