15. Current Day (Display Code CD)
Press the Extra Cycle button. Use this display to set the
current day on systems that have been configured as Day
of Week controls. This setting is identified by “CD” in the
upper left-hand corner of the
screen. Use the Up and Down
buttons to select from Day 1
through Day 7.
16. Flow Meter Type (Display
Code FM)
Press the Extra Cycle button. Use this display to set the type
of flow meter connected to the control. This option setting
is identified by “FM” in the
upper left-hand corner of the
screen. Use the Up and Down
buttons to select one of the 7
available settings.
16. Meter Pulse Setting (Display Code K)
Press the Extra Cycle button. Use this display to specify
the meter pulse setting for a non-standard flow meter. This
option setting is identified by “K” in the upper left-hand
corner of the screen. Use
the Up and Down buttons to
enter the meter constant in
pulses per unit volume.
17. Press the Extra Cycle button to save all settings and exit
Master Programming Mode.
10
CAUTION: Before entering Master Programming, please contact your local professional water dealer.
Master Programming Mode
12. Regeneration Cycle Step Times
Press the Extra Cycle button. Use this display to set the
Regeneration Cycle Step Times. The different regeneration
cycles are listed in sequence based on the valve
type selected for the system, and are identified by an
abbreviation in the upper left-hand corner of the screen.
The abbreviations used are listed below. If the system
has been configured with the “OTHER” valve type, the
regeneration cycles will be identified as R1, R2, R3, R4, R5,
and R6. Each cycle step time can be set from 0 to 199
minutes, or “OFF.” Setting a cycle step to “OFF” will disable
all of the following steps. Setting a cycle step time to 0 will
cause the control to skip that step during regeneration, but
keeps the following steps available. Use the Up and Down
buttons to adjust the value as needed. Press the Extra Cycle
button to accept the current setting and move to the next
parameter.
13. Day of Week Settings
Press the Extra Cycle button. Use this display to set the
regeneration schedule for a system configured as a Day of
Week control. The different days of the week are identified
as D1, D2, D3, D4, D5, D6, and D7 in the upper left-hand
corner of the display. Set the value to “ON” to schedule
a regeneration or “OFF” to skip regeneration for each
day. Use the Up and Down buttons to adjust the setting as
needed. Press the Extra Cycle button to accept the setting
and move to the next day. Note that the control requires at
least one day to be set to
“ON.” If all 7 days are set to
“OFF”, the unit will return to
Day One until one or more
days are set to “ON.”
BD
60
BW
10
RR
10
BF
12
Range: 0-199 minutes
Cycle Step Abbreviation
BD
Brine Draw
BW
Backwash
RR
Rapid Rinse
BF
Brine Refill
SV
Service
t0.7
Fleck 3/4” Turbine Meter
P0.7
Fleck 3/4” Paddle Wheel Meter
t1.0
Fleck 1” Turbine Meter
P1.0
Fleck 1” Paddle Wheel Meter
t1.5
Fleck 1-1/2” Turbine Meter
P1.5
Fleck 1-1/2” Paddle Wheel Meter
GEn
Generic/Other Meter
Содержание 6200 SXT
Страница 1: ...6200 SXT Upflow Control Valve for Water Conditioning and Treatment Purposes Service Manual...
Страница 21: ...Wiring Diagram 21...
Страница 22: ...6200SXT Upflow Brining Rates 22 6200SXT Upflow Brining Rates with Water 20 PSI Regulated Cap...
Страница 29: ...29 6200 SXT Valve Dimensional Drawings All dimensions are in Inches mm...
Страница 35: ...35...