Water balancing should be carried out as required to ensure water is balanced within the
following parameters. Within these tolerances, be balanced to the Langelier Saturation
Index within a range of -0.5 to +0.5.
When operating using hydrogen peroxide the following operating parameters are
recommended
Test
Result
Perox Pro (hydrogen peroxide)
100ppm - 300ppm
pH level
7.2 - 7.6
Total Alkalinity level
60ppm - 80ppm
Calcium Hardness
180ppm - 400ppm
Salinity (= total Pool salt & Mineral Crystals) For low salt
cell use*
2000ppm-3000ppm
Phosphate level
Less than < 0.5ppm
Chlorine Dioxide
0.4ppm - 0.5 ppm
When operating on chlorine the following operating parameters are recommended:
Test
Result
Residual sanitiser chlorine
1.0ppm
–
3.0ppm
pH level
7.2-7.6
Total Alkalinity level
100ppm
–
150ppm
Calcium Hardness
180ppm
–
400ppm
Salinity (= total Pool salt & Mineral Crystals) For low salt cell
use*
2000ppm-3000ppm
Phosphate level (ppm)
Less than < 0.5ppm
More frequent testing may be required in periods of extremely high usage or significant
water dilution, and maintenance may be required.
PLEASE NOTE:
The above information is a guide only. Please refer to the local laws that
govern a swimming pool or spa operation in your area. Always operate the system in
compliance with local laws.
8.1.2
Low levels of hydrogen peroxide
Low levels of hydrogen peroxide will fail to maintain a safe and pristine pool. Therefore,
always ensure that the levels are maintained at 100-150ppm.
8.1.3
Shock dose
From time to time, it is good practice to shock dose the pool with Perox Sanitiser. This
should ideally be done at the time of adding Perox Activate. Follow dose rates on the
container to achieve a 250ppm hydrogen peroxide level. Bathers should not swim whilst the
hydrogen peroxide level is above 450ppm.
Содержание OXISWIM
Страница 1: ...D U A L S A N I T I S A T I O N Installation and Operation manual Version 1 1 3 December 2022 ...
Страница 11: ...OXISWIM MANUAL P a g e 11 45 INSTALLATION AND COMMISSIONING ...
Страница 15: ...OXISWIM MANUAL P a g e 15 45 Oxiswim Typical Installation Layout ...
Страница 28: ...OXISWIM MANUAL P a g e 28 45 OPERATION AND MAINTENANCE ...